Fault-Tolerant Control for Power Converter in Switched Reluctance Motor (SRM) Applications

If an error occurs in one or more phases of the converter, the shaft torque will decrease, resulting in a reduction in speed. Additionally, the motor will vibrate and produce significant noise when operating intermittently. This research investigates a fault-tolerant circuit for an asymmetric H-bridge converter. The experimental setup includes a 3-phase switched reluctance motor with 12 stator poles and 8 rotor poles, an asymmetric H-bridge converter circuit utilizing a dSPACE DS1202 for processing, and a 48 V power supply. The accuracy of the proposed fault-tolerant circuit was confirmed through experiments, specifically when the switch in phase B or C of the 3-phase switched reluctance motor opened. The motor was able to return to normal operation.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.23919/icems60997.2024.10921230
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault-Tolerant Control for Power Converter in Switched Reluctance Motor (SRM) Applications

Ehsan Jamshidpour, Noureddine Takorabet, Paisak Poolphaka, Thierry Lubin et al.
Electric Motor Design and Analysis
article

Fault-Tolerant Control for Power Converter in Switched Reluctance Motor (SRM) Applications

Ehsan Jamshidpour, Noureddine Takorabet, Paisak Poolphaka, Thierry Lubin, Pairote Thongprasri
article en

Abstract

If an error occurs in one or more phases of the converter, the shaft torque will decrease, resulting in a reduction in speed. Additionally, the motor will vibrate and produce significant noise when operating intermittently. This research investigates a fault-tolerant circuit for an asymmetric H-bridge converter. The experimental setup includes a 3-phase switched reluctance motor with 12 stator poles and 8 rotor poles, an asymmetric H-bridge converter circuit utilizing a dSPACE DS1202 for processing, and a 48 V power supply. The accuracy of the proposed fault-tolerant circuit was confirmed through experiments, specifically when the switch in phase B or C of the 3-phase switched reluctance motor opened. The motor was able to return to normal operation.

Kasetsart University (TH), Groupe de Recherche en Énergie Électrique de Nancy (FR), Groupe de Recherche Clinique en Neuro-urologie (FR), Université de Lorraine (FR)
King Mongkut's University of Technology North Bangkok
Affordable and clean energy
Openalex Percentile: Top 74%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.