Transient Stability Evaluation of 132kV Transmission Network for Improved Power Quality

Transient instability in the power system leads to voltage collapse and consequently outages. This paper proposed the formulation and use of a 4th-order Runge-Kutta and a conventional swing equation for the 132 kV power transmission network from the Afam generating station to the Port Harcourt main (zone-2) injection substation. The initiated faults are not expected to last longer than necessary in the occurrence of a fault. This means that relays must provide automatic signaling communication to dedicated protective devices for isolation to avoid system interruption and breakdown. Numerical data were collated from the Transmission Company of Nigeria (TCN) to analyze the study case under investigation. The electrical transient analyzer tool (ETAP) was used to model and simulate the given preset value circuit breaker and relay time setting of 0.00, 0.02, 0.04, 0.06, 0.10, 0.12, and 0.14, respectively, on the view to investigate and evaluate parameters of rotor angle (δ), angular speed (w), and rotor-differential change (dδ/dt). The protective relay to coordination considered 10-cycle operation to the relay time setting of t=0.2 seconds, which must be responsive to clear faults as quickly as possible to enhance reliable power supply. The obtained results vividly indicate that the fourth (4th) order Runge-Kutta numerical technique tends to restore fault conditions and become stable and accurate with a fast response time of 0.02 seconds. It provides a lower absolute error of - 51% with power transfer capability from 0.00 pu to 3.7870 pu. This significantly means that the relays/protective device actions to system abnormal condition restoration time for stability were adequate during transient behavior as compared to other numerical solutions (modified Euler technique, etc.) for power system evaluation and analysis.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.1109/nigercon62786.2024.10927158
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Stability Evaluation of 132kV Transmission Network for Improved Power Quality

Ayodeji Olalekan Salau, Sepiribo Lucky Braide, Tayo Uthman Badrudeen, Shaimaa Hadi Mohmmed et al.
Power Systems and Technologies
article

Transient Stability Evaluation of 132kV Transmission Network for Improved Power Quality

Ayodeji Olalekan Salau, Sepiribo Lucky Braide, Tayo Uthman Badrudeen, Shaimaa Hadi Mohmmed, Israa Zamel Jiyad
article en

Abstract

Transient instability in the power system leads to voltage collapse and consequently outages. This paper proposed the formulation and use of a 4th-order Runge-Kutta and a conventional swing equation for the 132 kV power transmission network from the Afam generating station to the Port Harcourt main (zone-2) injection substation. The initiated faults are not expected to last longer than necessary in the occurrence of a fault. This means that relays must provide automatic signaling communication to dedicated protective devices for isolation to avoid system interruption and breakdown. Numerical data were collated from the Transmission Company of Nigeria (TCN) to analyze the study case under investigation. The electrical transient analyzer tool (ETAP) was used to model and simulate the given preset value circuit breaker and relay time setting of 0.00, 0.02, 0.04, 0.06, 0.10, 0.12, and 0.14, respectively, on the view to investigate and evaluate parameters of rotor angle (δ), angular speed (w), and rotor-differential change (dδ/dt). The protective relay to coordination considered 10-cycle operation to the relay time setting of t=0.2 seconds, which must be responsive to clear faults as quickly as possible to enhance reliable power supply. The obtained results vividly indicate that the fourth (4th) order Runge-Kutta numerical technique tends to restore fault conditions and become stable and accurate with a fast response time of 0.02 seconds. It provides a lower absolute error of - 51% with power transfer capability from 0.00 pu to 3.7870 pu. This significantly means that the relays/protective device actions to system abnormal condition restoration time for stability were adequate during transient behavior as compared to other numerical solutions (modified Euler technique, etc.) for power system evaluation and analysis.

Afe Babalola University (NG), Oduduwa University (NG), Ministry of Higher Education and Scientific Research (IQ), Rivers State University (NG)
Affordable and clean energy
Openalex Percentile: Top 74%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.