Multilayer, Multiband Compact Wearable Endfire Antenna for On-Body Communication

This paper investigates a compact, multilayered, multiband end-fire Yagi-Uda antenna through simulation in free space and on phantom. The antenna's design utilizes alternating layers of denim and latex substrates to achieve the desired end-fire radiation pattern. The proposed structure with phantom demonstrates three distinct end-fire radiations at resonant frequencies of 4.82 GHz, 5.22 GHz, and 5.65 GHz, with beam directions at angles of 22°, 40°, and 9°, and corresponding main beam directivities of 8.56 dBi, 9.25 dBi, and 3.60 dBi, respectively. To enhance beam performance near the human body and ensure compliance with Specific Absorption Rate (SAR) requirements, a 0.1 mm thick aluminum layer is added to the antenna's rear side. SAR analyses for 1 g and 10 g of tissue yielded values of 1.42 W/kg and 0.54 W/kg, respectively, meeting international safety standards.

Authors

Institutions

Publication Details

Published
2025-02-19
DOI
https://doi.org/10.1109/iwat64079.2025.10931218
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multilayer, Multiband Compact Wearable Endfire Antenna for On-Body Communication

Daniel Agu, Douglas E. Dow, Jayshri Kulkarni, Yang Li
Wireless Body Area Networks
article

Multilayer, Multiband Compact Wearable Endfire Antenna for On-Body Communication

Daniel Agu, Douglas E. Dow, Jayshri Kulkarni, Yang Li
article en

Abstract

This paper investigates a compact, multilayered, multiband end-fire Yagi-Uda antenna through simulation in free space and on phantom. The antenna's design utilizes alternating layers of denim and latex substrates to achieve the desired end-fire radiation pattern. The proposed structure with phantom demonstrates three distinct end-fire radiations at resonant frequencies of 4.82 GHz, 5.22 GHz, and 5.65 GHz, with beam directions at angles of 22°, 40°, and 9°, and corresponding main beam directivities of 8.56 dBi, 9.25 dBi, and 3.60 dBi, respectively. To enhance beam performance near the human body and ensure compliance with Specific Absorption Rate (SAR) requirements, a 0.1 mm thick aluminum layer is added to the antenna's rear side. SAR analyses for 1 g and 10 g of tissue yielded values of 1.42 W/kg and 0.54 W/kg, respectively, meeting international safety standards.

Baylor University (US), Wentworth Institute of Technology (US)
Affordable and clean energy
Openalex Percentile: Top 95%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.