Projection Pattern Precorrection Method Based on Projection Error Decoupling in Fringe Projection Profilometry

The quality of sinusoidal fringe projection is one of the most critical factors affecting the accuracy of fringe projection profilometry (FPP). Existing projection error correction methods, however, fail to address the simultaneous occurrence and mutual influence of geometric distortion and grayscale inconsistency in the actual projected pattern. In order to tackle this issue, this article proposes a projection pattern precorrection method based on projection error decoupling. By using multiangle expanded Gray code (MEGC), this method decouples the projection error correction process into two independent correction processes. Specifically, for the projection distortion error, a per-pixel distortion error calibration method is introduced. This method improves the accuracy of phase coordinate calculation by designing an encoding method for multiangle floating-point coordinates and a decoding method for weighted fusion of multi coordinate values. It compensates for the distortion error pixel by pixel using a nonparametric form. A subregional nonlinear error calibration method is, furthermore, proposed to enhance the sinusoidal quality of the projected fringes and ensure grayscale consistency. Finally, the precorrected pattern is generated based on the two error calibration results which ensures distortion-free and brightness-accurate fringe pattern. Experimental results with various 3-D objects demonstrated that our proposed method, achieves higher and more stable measurement accuracy (average 0.0327 mm versus 0.0184 mm), compared with traditional precorrection methods that address projection errors separately.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3553566
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Projection Pattern Precorrection Method Based on Projection Error Decoupling in Fringe Projection Profilometry

Jianrong Tan, Guodong Sa, Zhenyu Liu, Junkai Ge et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Optical measurement and interference techniques
1.28
article

Projection Pattern Precorrection Method Based on Projection Error Decoupling in Fringe Projection Profilometry

Jianrong Tan, Guodong Sa, Zhenyu Liu, Junkai Ge, Peng Tang
article en
1 citations

Abstract

The quality of sinusoidal fringe projection is one of the most critical factors affecting the accuracy of fringe projection profilometry (FPP). Existing projection error correction methods, however, fail to address the simultaneous occurrence and mutual influence of geometric distortion and grayscale inconsistency in the actual projected pattern. In order to tackle this issue, this article proposes a projection pattern precorrection method based on projection error decoupling. By using multiangle expanded Gray code (MEGC), this method decouples the projection error correction process into two independent correction processes. Specifically, for the projection distortion error, a per-pixel distortion error calibration method is introduced. This method improves the accuracy of phase coordinate calculation by designing an encoding method for multiangle floating-point coordinates and a decoding method for weighted fusion of multi coordinate values. It compensates for the distortion error pixel by pixel using a nonparametric form. A subregional nonlinear error calibration method is, furthermore, proposed to enhance the sinusoidal quality of the projected fringes and ensure grayscale consistency. Finally, the precorrected pattern is generated based on the two error calibration results which ensures distortion-free and brightness-accurate fringe pattern. Experimental results with various 3-D objects demonstrated that our proposed method, achieves higher and more stable measurement accuracy (average 0.0327 mm versus 0.0184 mm), compared with traditional precorrection methods that address projection errors separately.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Ningbo University (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 22%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.