Training a Regulatory Team to Use the Odor Profile Method for Evaluation of Atmospheric Malodors

Members of the California Air Resources Board (CARB) participated in the odor profile method (OPM) training program. The OPM is the flavor profile analysis (FPA) standard method applied to air samples. The FPA method is a widely used standard method in drinking water taste and odor evaluations. It was found that pre-screening of potential OPM trainees for anosmia cases was necessary. After odor characteristics were defined by odor references and standardized terminology, the trainees were able to accurately describe single odors. However, the trainees could not always simultaneously perceive all odors within a mixture. Therefore, a method to separate the odors in a mixture should be applied in the future for environmental analysis by the OPM. After a half-day training session every day for a week, a panel could be formed to accurately determine the characteristics of atmospheric odors from various facilities. With the help of an intensity scale defined by sugar solutions, the panel could also report average odor intensity values consistent with the facilities’ operation. However, a high variance of individual intensity values relative to panel average was noted. It was likely caused by the simultaneous presence of multiple odors in the air and a lack of definition of low odor intensity values by sugar solutions. Secondly, lower odor intensities were reported when sampling bags were used for the OPM analysis compared to direct sniffing at the facilities’ fenceline, apparently because of the narrow valve opening of the sampling bags. The feasibility of quick adoption of the OPM by a regulatory team as demonstrated in this study is essential for the OPM to be considered as a method to evaluate atmospheric malodors as the FPA for drinking water analysis.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2025-03-23
DOI
https://doi.org/10.3390/atmos16040362
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Training a Regulatory Team to Use the Odor Profile Method for Evaluation of Atmospheric Malodors

I. H. Suffet, Tobias Bader, Lily F. Lee, Zhihang Yin et al.
1 citations
Atmosphere
Advanced Chemical Sensor Technologies
0.67
article

Training a Regulatory Team to Use the Odor Profile Method for Evaluation of Atmospheric Malodors

I. H. Suffet, Tobias Bader, Lily F. Lee, Zhihang Yin, Regina McDaniels
article en
1 citations

Abstract

Members of the California Air Resources Board (CARB) participated in the odor profile method (OPM) training program. The OPM is the flavor profile analysis (FPA) standard method applied to air samples. The FPA method is a widely used standard method in drinking water taste and odor evaluations. It was found that pre-screening of potential OPM trainees for anosmia cases was necessary. After odor characteristics were defined by odor references and standardized terminology, the trainees were able to accurately describe single odors. However, the trainees could not always simultaneously perceive all odors within a mixture. Therefore, a method to separate the odors in a mixture should be applied in the future for environmental analysis by the OPM. After a half-day training session every day for a week, a panel could be formed to accurately determine the characteristics of atmospheric odors from various facilities. With the help of an intensity scale defined by sugar solutions, the panel could also report average odor intensity values consistent with the facilities’ operation. However, a high variance of individual intensity values relative to panel average was noted. It was likely caused by the simultaneous presence of multiple odors in the air and a lack of definition of low odor intensity values by sugar solutions. Secondly, lower odor intensities were reported when sampling bags were used for the OPM analysis compared to direct sniffing at the facilities’ fenceline, apparently because of the narrow valve opening of the sampling bags. The feasibility of quick adoption of the OPM by a regulatory team as demonstrated in this study is essential for the OPM to be considered as a method to evaluate atmospheric malodors as the FPA for drinking water analysis.

AtmosphereVol. 16(4)
California Air Resources Board (US), University of California, Los Angeles (US)
California Air Resources Board
Openalex Percentile: Top 34%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.