RSTAR4D: Rotational Streak Artifact Reduction in 4-D CBCT Using Separable 4-D Convolutions
Four-dimensionalcone-beam computed tomography (4-D CBCT) provides respiration-resolved images and facilitates image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw projection data are sorted into multiple respiratory phases, the reconstructed 4-D CBCT images are covered by severe streak artifacts. Although several deep learning-based methods have been proposed to address this issue, most algorithms formulate it as a 2-D image enhancement task, neglecting the dynamic nature of 4-D CBCT. In this article, we first identify the origin and appearance of streak artifacts in 4-D CBCT images. We find that streak artifacts exhibit a unique “rotational motion” along with the patient’s respiration, distinguishable from diaphragm-driven respiratory motion in 4-D space. Therefore, we introduce RSTAR4D-Net, a 4-D model that performs rotational streak artifact reduction by exploring the dynamic prior of 4-D CBCT images. Specifically, we overcome the computational and training difficulties of a 4-D neural network. The specially designed model decomposes the 4-D convolutions into multiple lower-dimensional operations and thus efficiently processes a whole 4-D image. Additionally, a Tetris training strategy is proposed to effectively train the model using limited 4-D data. Extensive experiments substantiate the superior performance of RSTAR4D-Net compared to existing methods.
Authors
- Z. Deng (ORCID: https://orcid.org/0000-0003-2595-9122)
- Tianling Lyu (ORCID: https://orcid.org/0000-0002-5851-6363)
- Yan Xi (ORCID: https://orcid.org/0000-0001-6143-3107)
- Hua Chen (ORCID: https://orcid.org/0000-0002-1563-5274)
- Jun Zhao (ORCID: https://orcid.org/0000-0002-3539-2249)
- Yongzheng Zhou
- Yang Chen (ORCID: https://orcid.org/0000-0002-5660-6349)
- Jiayuan Sun (ORCID: https://orcid.org/0009-0002-9569-131X)
- Zhiyong Xu (ORCID: https://orcid.org/0000-0002-5722-8271)
- Haibo Hu (ORCID: https://orcid.org/0000-0001-8442-5222)
Institutions
- Shanghai Jiao Tong University (CN)
- Shanghai Chest Hospital (CN)
- United Imaging Healthcare (China) (CN)
- Southeast University (CN)
Publication Details
- Journal
- IEEE Transactions on Radiation and Plasma Medical Sciences
- Published
- 2025-03-24
- DOI
- https://doi.org/10.1109/trpms.2025.3553866
- Citations
- 1
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36
Funders
- National Key Research and Development Program of China