Comparative Analysis of the Histological Characteristics of Bone Tissue Following Implant Drill Preparation Under Various Parameters: An In Vitro Study

<b>Purpose:</b> This study aimed to compare the histological characteristics of bone tissue following drilling with three implant systems under different rotational speeds and cooling conditions. <b>Methods:</b> A total of 54 implant bed preparations were performed in four swine ribs using three implant systems: Hiossen ET (Hiossen, Fairfield, NJ, USA), Paltop (Burlington, MA, USA), and Anyridge (Megagen, Daegu, Republic of Korea). Drilling was performed at three speeds (800, 1200, and 1500 rpm) under three cooling conditions: saline at room temperature, saline cooled to 4 °C, and no cooling. Histological evaluation was conducted using a Nikon Eclipse 80i fluorescence microscope (Nikon, Tokyo, Japan) with DAPI and rhodamine staining. Observations were performed at 40× magnification, focusing on the osteotomy wall and surrounding tissue. The samples were assessed based on surface smoothness, compressed tissue presence, carbonization, and adjacent tissue damage. Statistical analysis was performed using the Kruskal-Wallis test with Dunn's post hoc comparisons to evaluate differences among experimental conditions. <b>Results:</b> The results demonstrated that the Hiossen ET system achieved optimal bone bed quality at 1200 rpm with saline cooling at 4 °C, producing the smoothest osteotomy walls and minimal thermal damage (<i>p</i> = 0.003). The Paltop system performed best at 800 rpm with 4 °C cooling, showing reduced tissue compression and fewer microcracks (<i>p</i> = 0.012). The Anyridge system exhibited the most favorable outcomes at 1200 rpm with saline cooling at room temperature, minimizing soft tissue remnants and preserving bone integrity (<i>p</i> = 0.021). Across all systems, the absence of cooling significantly increased thermal damage, carbonization, and tissue fragmentation, particularly at 1500 rpm (<i>p</i> < 0.001). <b>Conclusions:</b> The use of lower rotational speeds with effective cooling minimized tissue trauma and improved bone bed integrity. Further clinical validation is necessary to confirm the applicability of these results in human bone.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-21
DOI
https://doi.org/10.3390/jcm14072161
Citations
3
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
5.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of the Histological Characteristics of Bone Tissue Following Implant Drill Preparation Under Various Parameters: An In Vitro Study

Jacek Matys, Michał Kulus, Maciej Dobrzyński, Piotr Kuropka et al.
3 citations
Journal of Clinical Medicine
Dental Implant Techniques and Outcomes
5.37
article

Comparative Analysis of the Histological Characteristics of Bone Tissue Following Implant Drill Preparation Under Various Parameters: An In Vitro Study

Jacek Matys, Michał Kulus, Maciej Dobrzyński, Piotr Kuropka, Piotr Kosior, Natalia Struzik, Maria Wiśniewska-Wrona
article en
3 citations

Abstract

<b>Purpose:</b> This study aimed to compare the histological characteristics of bone tissue following drilling with three implant systems under different rotational speeds and cooling conditions. <b>Methods:</b> A total of 54 implant bed preparations were performed in four swine ribs using three implant systems: Hiossen ET (Hiossen, Fairfield, NJ, USA), Paltop (Burlington, MA, USA), and Anyridge (Megagen, Daegu, Republic of Korea). Drilling was performed at three speeds (800, 1200, and 1500 rpm) under three cooling conditions: saline at room temperature, saline cooled to 4 °C, and no cooling. Histological evaluation was conducted using a Nikon Eclipse 80i fluorescence microscope (Nikon, Tokyo, Japan) with DAPI and rhodamine staining. Observations were performed at 40× magnification, focusing on the osteotomy wall and surrounding tissue. The samples were assessed based on surface smoothness, compressed tissue presence, carbonization, and adjacent tissue damage. Statistical analysis was performed using the Kruskal-Wallis test with Dunn's post hoc comparisons to evaluate differences among experimental conditions. <b>Results:</b> The results demonstrated that the Hiossen ET system achieved optimal bone bed quality at 1200 rpm with saline cooling at 4 °C, producing the smoothest osteotomy walls and minimal thermal damage (<i>p</i> = 0.003). The Paltop system performed best at 800 rpm with 4 °C cooling, showing reduced tissue compression and fewer microcracks (<i>p</i> = 0.012). The Anyridge system exhibited the most favorable outcomes at 1200 rpm with saline cooling at room temperature, minimizing soft tissue remnants and preserving bone integrity (<i>p</i> = 0.021). Across all systems, the absence of cooling significantly increased thermal damage, carbonization, and tissue fragmentation, particularly at 1500 rpm (<i>p</i> < 0.001). <b>Conclusions:</b> The use of lower rotational speeds with effective cooling minimized tissue trauma and improved bone bed integrity. Further clinical validation is necessary to confirm the applicability of these results in human bone.

Journal of Clinical MedicineVol. 14(7)
Wrocław University of Environmental and Life Sciences (PL), Wroclaw Medical University (PL)
Uniwersytet Medyczny im. Piastów Slaskich we Wroclawiu
Openalex Percentile: Top 5%
Dental Implant Techniques and Outcomes
5.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.