Development of a wearable system to estimate knee adduction moment of patients with knee osteoarthritis during gait using a single inertial measurement unit

The external knee adduction moment (KAM) during gait is an important mechanical factor for knee osteoarthritis (KOA). Three-dimensional motion capture (MoCap) has been used to measure KAM, but it has limitations including cost, measuring time, and space. The purpose of this study was to develop a simple and wearable system to estimate KAM. Thirty-nine female and seven male subjects diagnosed with KOA were included. Simultaneous measurements of 5 ​m walk using MoCap and inertial measurement unit (IMU) attached to the knee were performed, and a deep learning algorithm based on a gait phase detection algorithm and one-dimensional convolutional neural network model was used to estimate KAM. In addition, the reliability of the artificial intelligence system was also evaluated. The mean absolute percent error (MAPE) and mean absolute error (MAE) of estimated KAM peak of the training data and test datasets were 13.0% and 0.0428 Nm.s/(BW∗Ht) and 17.3% and 0.0505 Nm.s/(BW∗Ht), respectively, and those of estimated KAM impulse were 20.4% and 0.0214 Nm.s/(BW∗Ht) and 21.4% and 0.0212 Nm.s/(BW∗Ht), respectively. The Pearson correlation coefficients between estimated KAM (peak, impulse) and MoCap KAM (peak, impulse) were 0.870 and 0.975 in the training dataset and 0.591 and 0.690 in the test dataset. The intraclass correlation coefficients (ICCs) of estimated KAM impulse were 0.83, 0.94, 0.70, and 0.82 for ICCs (1.1), (1,k), (2,1), and (2,k) respectively. The wearable system showed reasonable accuracy and reliability in estimating KAM of KOA during gait. The simple equipment in the system enables the measurement of KAM during daily practice in the clinic or hospital if there is available space to walk 5 ​m. • A wearable system estimates knee adduction moment (KAM) using a single sensor. • The system provides a cost-effective alternative to traditional motion capture. • Deep learning algorithms enhance the accuracy and reliability of KAM estimation. • The system allows KAM assessment in clinical settings with minimal equipment.

Authors

Institutions

Publication Details

Journal
Journal of Joint Surgery and Research
Published
2025-03-24
DOI
https://doi.org/10.1016/j.jjoisr.2025.02.005
Citations
2
Primary Topic
Osteoarthritis Treatment and Mechanisms
Type
article
Field-Weighted Citation Impact
3.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a wearable system to estimate knee adduction moment of patients with knee osteoarthritis during gait using a single inertial measurement unit

Masaya Nakamura, Kengo Harato, Kohei Nishizawa, Hiroshi Yoshihara et al.
2 citations
Journal of Joint Surgery and Research
Osteoarthritis Treatment and Mechanisms
3.34
article

Development of a wearable system to estimate knee adduction moment of patients with knee osteoarthritis during gait using a single inertial measurement unit

Masaya Nakamura, Kengo Harato, Kohei Nishizawa, Hiroshi Yoshihara, Takeo Nagura, Yu Iwama, Ayako Akiba
article en
2 citations

Abstract

The external knee adduction moment (KAM) during gait is an important mechanical factor for knee osteoarthritis (KOA). Three-dimensional motion capture (MoCap) has been used to measure KAM, but it has limitations including cost, measuring time, and space. The purpose of this study was to develop a simple and wearable system to estimate KAM. Thirty-nine female and seven male subjects diagnosed with KOA were included. Simultaneous measurements of 5 ​m walk using MoCap and inertial measurement unit (IMU) attached to the knee were performed, and a deep learning algorithm based on a gait phase detection algorithm and one-dimensional convolutional neural network model was used to estimate KAM. In addition, the reliability of the artificial intelligence system was also evaluated. The mean absolute percent error (MAPE) and mean absolute error (MAE) of estimated KAM peak of the training data and test datasets were 13.0% and 0.0428 Nm.s/(BW∗Ht) and 17.3% and 0.0505 Nm.s/(BW∗Ht), respectively, and those of estimated KAM impulse were 20.4% and 0.0214 Nm.s/(BW∗Ht) and 21.4% and 0.0212 Nm.s/(BW∗Ht), respectively. The Pearson correlation coefficients between estimated KAM (peak, impulse) and MoCap KAM (peak, impulse) were 0.870 and 0.975 in the training dataset and 0.591 and 0.690 in the test dataset. The intraclass correlation coefficients (ICCs) of estimated KAM impulse were 0.83, 0.94, 0.70, and 0.82 for ICCs (1.1), (1,k), (2,1), and (2,k) respectively. The wearable system showed reasonable accuracy and reliability in estimating KAM of KOA during gait. The simple equipment in the system enables the measurement of KAM during daily practice in the clinic or hospital if there is available space to walk 5 ​m. • A wearable system estimates knee adduction moment (KAM) using a single sensor. • The system provides a cost-effective alternative to traditional motion capture. • Deep learning algorithms enhance the accuracy and reliability of KAM estimation. • The system allows KAM assessment in clinical settings with minimal equipment.

Journal of Joint Surgery and ResearchVol. 3(2)
Keio University (JP), Keio University Hospital (JP), Department of Health (IE), Kitasato Institute Hospital (JP), The University of Tokyo (JP)
Gender equality
Openalex Percentile: Top 10%
Osteoarthritis Treatment and Mechanisms
3.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.