Impedance monitoring of a plasma chamber under plasma-off conditions for contamination control

Abstract Changes in the conditions of a plasma process chamber often cause process shifts during plasma processes. We studied the chamber impedance monitoring under off-plasma conditions. As the deposition process continues, film residues accumulate on the chamber showerhead and components, potentially altering the impedance in the process chamber. When measured by a vector network analyzer (VNA), the reactance component increases significantly in the negative region. Notably, a strong correlation ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msup> <mml:mrow> <mml:mi>R</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> <mml:mo>=</mml:mo> <mml:mn>0.99</mml:mn> </mml:math> ) was observed between the height of the SiF 3 peak, indicative of the contamination level during the in situ dry cleaning (ISD) step. This correlation was attributed to an increase in the capacitance component within the chamber, as verified through equivalent circuit analysis. These results demonstrate the feasibility of monitoring chamber contamination even in the off-plasma state.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-03-24
DOI
https://doi.org/10.35848/1347-4065/adc461
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedance monitoring of a plasma chamber under plasma-off conditions for contamination control

Hwanggyu Kim, Sang Jeen Hong
Japanese Journal of Applied Physics
Plasma Diagnostics and Applications
article

Impedance monitoring of a plasma chamber under plasma-off conditions for contamination control

Hwanggyu Kim, Sang Jeen Hong
article en

Abstract

Abstract Changes in the conditions of a plasma process chamber often cause process shifts during plasma processes. We studied the chamber impedance monitoring under off-plasma conditions. As the deposition process continues, film residues accumulate on the chamber showerhead and components, potentially altering the impedance in the process chamber. When measured by a vector network analyzer (VNA), the reactance component increases significantly in the negative region. Notably, a strong correlation ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:msup> <mml:mrow> <mml:mi>R</mml:mi> </mml:mrow> <mml:mrow> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> <mml:mo>=</mml:mo> <mml:mn>0.99</mml:mn> </mml:math> ) was observed between the height of the SiF 3 peak, indicative of the contamination level during the in situ dry cleaning (ISD) step. This correlation was attributed to an increase in the capacitance component within the chamber, as verified through equivalent circuit analysis. These results demonstrate the feasibility of monitoring chamber contamination even in the off-plasma state.

Japanese Journal of Applied PhysicsVol. 64(4)
Myongji University (KR)
Openalex Percentile: Top 95%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impedance monitoring of a plasma chamber under plasma-off conditions for contamination control — Hwanggyu Kim, Sang Jeen Hong · Japanese Journal of Applied Physics (2025) | TGRS Research Map | TGRS