Possibilities to improve measuring precision of the dispersion energy with an adhered cantilever <sup>(a)</sup>

Abstract Measurement of the Casimir forces at distances smaller than 50 nm is a complicated problem. The method of adhered cantilever does not suffer from loss of stability at short distances and was used recently to measure the adhesion energy due to the dispersion forces with a precision of 10%. In this paper the most important source of errors related to inhomogeneity of the thickness of the cantilevers is discussed. Analytical expressions for the shape of an inhomogeneous cantilever and the adhesion energy are derived. It is demonstrated that monitoring of the cantilever thickness along its length allows five times improvement of the precision. A small twisting of the cantilevers is indicated as an additional source of important errors. This parameter controls the precision of equilibrium average distance between the surfaces and the true adhesion energy between parallel plates.

Authors

Institutions

Publication Details

Journal
Europhysics Letters (EPL)
Published
2025-03-24
DOI
https://doi.org/10.1209/0295-5075/adc47f
Citations
2
Primary Topic
Quantum Electrodynamics and Casimir Effect
Type
article
Field-Weighted Citation Impact
2.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Possibilities to improve measuring precision of the dispersion energy with an adhered cantilever (a)

И. А. Солдатенков, V. B. Svetovoy
2 citations
Europhysics Letters (EPL)
Quantum Electrodynamics and Casimir Effect
2.49
article

Possibilities to improve measuring precision of the dispersion energy with an adhered cantilever (a)

И. А. Солдатенков, V. B. Svetovoy
article en
2 citations

Abstract

Abstract Measurement of the Casimir forces at distances smaller than 50 nm is a complicated problem. The method of adhered cantilever does not suffer from loss of stability at short distances and was used recently to measure the adhesion energy due to the dispersion forces with a precision of 10%. In this paper the most important source of errors related to inhomogeneity of the thickness of the cantilevers is discussed. Analytical expressions for the shape of an inhomogeneous cantilever and the adhesion energy are derived. It is demonstrated that monitoring of the cantilever thickness along its length allows five times improvement of the precision. A small twisting of the cantilevers is indicated as an additional source of important errors. This parameter controls the precision of equilibrium average distance between the surfaces and the true adhesion energy between parallel plates.

Europhysics Letters (EPL)Vol. 150(3)
Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences (RU), Institute for Problems in Mechanics (RU)
Ministry of Science and Higher Education of the Russian Federation
Affordable and clean energy
Openalex Percentile: Top 13%
Quantum Electrodynamics and Casimir Effect
2.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Possibilities to improve measuring precision of the dispersion energy with an adhered cantilever <sup>(a)</sup> — И. А. Солдатенков, V. B. Svetovoy · Europhysics Letters (EPL) (2025) | TGRS Research Map | TGRS