The Effects of Installation Faults of Air Conditioning Systems on Carbon Emissions

In this study, the effects of installation faults of condenser of Air Conditioning (AC) systems on emissions were investigated and Life Cycle Climate Performance (LCCP) analysis was carried out according to the scenario of installation faults of the condenser unit of the AC system for 12 countries. The heat taken by the evaporator units of the ACs is transferred to the condenser unit via the system. This thermal energy is transferred to the surrounding air via condenser. The surrounding air cannot pass through the condenser unit in desired amounts and causes more electricity consumption of the system due to installation faults. The rates of increase of the LCCP values change from 0.02% to 29.6% because of installation faults. The LCCP value was calculated as 19692 – 19858 kg∙CO2e with the closing of the air inlet because of installation faults for Turkey. Considering the installation faults of the condenser, the LCCP value was calculated as 21284 - 21505 kg∙CO2e for Japan.

Authors

Institutions

Publication Details

Journal
Turkish Journal of Science and Technology
Published
2025-03-25
DOI
https://doi.org/10.55525/tjst.1556618
Citations
2
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effects of Installation Faults of Air Conditioning Systems on Carbon Emissions

Ruveyda Ergen, Mert Gürtürk
2 citations
Turkish Journal of Science and Technology
Refrigeration and Air Conditioning Technologies
1.43
article

The Effects of Installation Faults of Air Conditioning Systems on Carbon Emissions

Ruveyda Ergen, Mert Gürtürk
article en
2 citations

Abstract

In this study, the effects of installation faults of condenser of Air Conditioning (AC) systems on emissions were investigated and Life Cycle Climate Performance (LCCP) analysis was carried out according to the scenario of installation faults of the condenser unit of the AC system for 12 countries. The heat taken by the evaporator units of the ACs is transferred to the condenser unit via the system. This thermal energy is transferred to the surrounding air via condenser. The surrounding air cannot pass through the condenser unit in desired amounts and causes more electricity consumption of the system due to installation faults. The rates of increase of the LCCP values change from 0.02% to 29.6% because of installation faults. The LCCP value was calculated as 19692 – 19858 kg∙CO2e with the closing of the air inlet because of installation faults for Turkey. Considering the installation faults of the condenser, the LCCP value was calculated as 21284 - 21505 kg∙CO2e for Japan.

Turkish Journal of Science and TechnologyVol. 20(1)
Fırat University (TR)
National Aeronautics and Space Administration, Langley Research Center
Openalex Percentile: Top 22%
Refrigeration and Air Conditioning Technologies
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.