Dose distribution comparison using image registration principles

Radiotherapy relies on accurate dose distribution comparison methods, but current approaches have limitations. This study introduces a novel algorithm based on image registration principles to address these limitations. The algorithm uses a transformation matrix derived from image registration to align an evaluated dose distribution with a reference distribution. This transformation employs multiple steps: detecting keypoints, constructing descriptors, matching keypoints, and estimating an affine transformation matrix. The transformed distribution is then directly comparable to the reference through linear least squares regression. Validation on 174 dose distribution pairs demonstrated robust performance, with bias and precision within clinically acceptable limits. Linearity assessments confirmed consistent behavior across a wide range of dose intensities. Comparisons with gamma analysis showed substantial agreement (Cohen's Kappa: 0.77), while additional metrics highlighted its clinical suitability: precision (0.98), recall (0.95), accuracy (0.94), specificity (0.86), and F1-score (0.96). These results establish the algorithm as a promising complement to gamma analysis, with strong potential for clinical integration. • A novel algorithm for dose distribution comparison is proposed, addressing limitations of current methods. • The algorithm matches isodose contours via affine registration for direct comparison using regression line slopes. • The algorithm was validated using 174 dose distribution pairs, achieving acceptable bias, precision, and linearity • Strong agreement with gamma analysis suggests potential for clinical integration. • Future work will extend the algorithm to 3D dose distribution comparison.

Authors

Institutions

Publication Details

Journal
Nuclear Analysis
Published
2025-03-24
DOI
https://doi.org/10.1016/j.nucana.2025.100170
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dose distribution comparison using image registration principles

Ouadie Kabach, I. Zidouh, El Mahjoub Chakir, Taher Elkhoukhi et al.
1 citations
Nuclear Analysis
Advanced Radiotherapy Techniques
1.88
article

Dose distribution comparison using image registration principles

Ouadie Kabach, I. Zidouh, El Mahjoub Chakir, Taher Elkhoukhi, Meryeme Bellahsaouia, Wafae Chfeq, Assia Arctout
article en
1 citations

Abstract

Radiotherapy relies on accurate dose distribution comparison methods, but current approaches have limitations. This study introduces a novel algorithm based on image registration principles to address these limitations. The algorithm uses a transformation matrix derived from image registration to align an evaluated dose distribution with a reference distribution. This transformation employs multiple steps: detecting keypoints, constructing descriptors, matching keypoints, and estimating an affine transformation matrix. The transformed distribution is then directly comparable to the reference through linear least squares regression. Validation on 174 dose distribution pairs demonstrated robust performance, with bias and precision within clinically acceptable limits. Linearity assessments confirmed consistent behavior across a wide range of dose intensities. Comparisons with gamma analysis showed substantial agreement (Cohen's Kappa: 0.77), while additional metrics highlighted its clinical suitability: precision (0.98), recall (0.95), accuracy (0.94), specificity (0.86), and F1-score (0.96). These results establish the algorithm as a promising complement to gamma analysis, with strong potential for clinical integration. • A novel algorithm for dose distribution comparison is proposed, addressing limitations of current methods. • The algorithm matches isodose contours via affine registration for direct comparison using regression line slopes. • The algorithm was validated using 174 dose distribution pairs, achieving acceptable bias, precision, and linearity • Strong agreement with gamma analysis suggests potential for clinical integration. • Future work will extend the algorithm to 3D dose distribution comparison.

Nuclear AnalysisVol. 4(2)
Abdelmalek Essaâdi University (MA), Université Ibn-Tofail (MA), National Centre for Nuclear Energy, Science and Technology (MA)
Openalex Percentile: Top 19%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.