Non-Invasive Monitoring of Intracranial Pressure Pulse Waves from Closed Eyelids in Patients with Normal-Tension Glaucoma

<i>Background and Objectives</i>: Normal-tension glaucoma (NTG) is a subtype of primary open-angle glaucoma characterized by progressive optic nerve damage despite intraocular pressure (IOP) remaining within the normal range. The underlying pathophysiology of NTG remains incompletely understood, and its diagnosis is often delayed due to the lack of a definitive screening tool. This study aimed to evaluate differences in intracranial pressure pulse wave amplitude recorded from closed eyelids between NTG patients and control subjects using a novel non-invasive monitoring technology. <i>Materials and Methods</i>: A cross-sectional observational study was conducted, enrolling NTG patients and age-matched controls. Intracranial pressure pulse wave signals were recorded from closed eyelids using the 'Archimedes' 02 device, which employs a highly sensitive digital pressure sensor and hydromechanical coupling for signal transmission. The amplitude of recorded intracranial pressure pulse waves was analyzed and compared between groups. Statistical analyses were performed using IBM SPSS Statistics 30.0, with significance set at <i>p</i> < 0.05. <i>Results</i>: A total of 140 participants were enrolled, including 68 NTG patients and 72 controls. After applying exclusion criteria, 63 NTG patients and 68 controls were included in the final analysis. The median intracranial pressure pulse wave amplitude was significantly higher in NTG patients (0.1326 a.u.) than in controls (0.0889 a.u.), with <i>p</i> = 0.01. <i>Conclusions</i>: These findings suggest that intracranial pressure pulse wave monitoring may serve as a potential biomarker for NTG. Further studies are needed to determine the diagnostic accuracy, sensitivity, and specificity of this technology for NTG detection.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-03-22
DOI
https://doi.org/10.3390/medicina61040566
Citations
2
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
3.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Monitoring of Intracranial Pressure Pulse Waves from Closed Eyelids in Patients with Normal-Tension Glaucoma

Austėja Judickaitė, Edvinas Chaleckas, Ingrida Janulevičienė, Yasin Hamarat et al.
2 citations
Medicina
Glaucoma and retinal disorders
3.41
article

Non-Invasive Monitoring of Intracranial Pressure Pulse Waves from Closed Eyelids in Patients with Normal-Tension Glaucoma

Austėja Judickaitė, Edvinas Chaleckas, Ingrida Janulevičienė, Yasin Hamarat, Fabien Scalzo, Laimonas Bartušis, Akvilė Stoškuvienė, Arminas Ragauskas, Mantas Deimantavičius, Solventa Krakauskaitė, Kristina Berškienė, Arminas Zizas, Ugne Kevalaite
article en
2 citations

Abstract

<i>Background and Objectives</i>: Normal-tension glaucoma (NTG) is a subtype of primary open-angle glaucoma characterized by progressive optic nerve damage despite intraocular pressure (IOP) remaining within the normal range. The underlying pathophysiology of NTG remains incompletely understood, and its diagnosis is often delayed due to the lack of a definitive screening tool. This study aimed to evaluate differences in intracranial pressure pulse wave amplitude recorded from closed eyelids between NTG patients and control subjects using a novel non-invasive monitoring technology. <i>Materials and Methods</i>: A cross-sectional observational study was conducted, enrolling NTG patients and age-matched controls. Intracranial pressure pulse wave signals were recorded from closed eyelids using the 'Archimedes' 02 device, which employs a highly sensitive digital pressure sensor and hydromechanical coupling for signal transmission. The amplitude of recorded intracranial pressure pulse waves was analyzed and compared between groups. Statistical analyses were performed using IBM SPSS Statistics 30.0, with significance set at <i>p</i> < 0.05. <i>Results</i>: A total of 140 participants were enrolled, including 68 NTG patients and 72 controls. After applying exclusion criteria, 63 NTG patients and 68 controls were included in the final analysis. The median intracranial pressure pulse wave amplitude was significantly higher in NTG patients (0.1326 a.u.) than in controls (0.0889 a.u.), with <i>p</i> = 0.01. <i>Conclusions</i>: These findings suggest that intracranial pressure pulse wave monitoring may serve as a potential biomarker for NTG. Further studies are needed to determine the diagnostic accuracy, sensitivity, and specificity of this technology for NTG detection.

MedicinaVol. 61(4)
Lithuanian University of Health Sciences (LT), University of California, Los Angeles (US), Kaunas University of Technology (LT), Hospital of Lithuanian University of Health Sciences Kaunas Clinics (LT)
Lietuvos Mokslo Taryba
Openalex Percentile: Top 10%
Glaucoma and retinal disorders
3.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.