High performance charge detection mass spectrometry without ultra-high vacuum

Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10<sup>-9</sup> Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10<sup>-6</sup> Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10<sup>-8</sup> Torr to 1 × 10<sup>-6</sup> Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00019j
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High performance charge detection mass spectrometry without ultra-high vacuum

Evan R. Williams, Zachary M. Miller, Emeline Hanozin, Jacob S. Jordan et al.
1 citations
The Analyst
Mass Spectrometry Techniques and Applications
0.76
article

High performance charge detection mass spectrometry without ultra-high vacuum

Evan R. Williams, Zachary M. Miller, Emeline Hanozin, Jacob S. Jordan, Conner C. Harper
article en
1 citations

Abstract

Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10<sup>-9</sup> Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10<sup>-6</sup> Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10<sup>-8</sup> Torr to 1 × 10<sup>-6</sup> Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.

The AnalystVol. 150(8)
University of California, Berkeley (US)
Arnold and Mabel Beckman Foundation, Belgian American Educational Foundation, Eli Lilly and Company, Merck, National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 33%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.