Integrated CFD and Experimental Analysis on Slinger Ring Condensate Discharge Mechanism for Energy-Efficient Window Air Conditioners

As global demand for energy-efficient cooling technologies grows, optimizing window air conditioners (WACs) is crucial. This study integrates computational fluid dynamics (CFD) and experimental fluid dynamics (EFD) to analyze condensate transport induced by the slinger ring in a WAC system. To investigate condensate behavior, the WAC domain is divided into six regions based on the slinger ring’s rotational direction and impact. In the initial impact zone, large liquid structures adhere to the slinger ring before breaking into ligaments. In the upward transport region, condensate films rise along the wall due to centrifugal forces, forming short ligaments. In the rebound region, condensate impacts the top surface and transitions into droplets. In the accumulation zone, droplet coalescence occurs in a confined space, leading to localized mass buildup. In the dispersion region, condensate spreads widely due to increased rotational speed. In the splash zone, splashing and wave-like structures form near the reservoir surface. A newly identified mechanism of condensate mass discharge shows that mass ejection is concentrated in four key regions near the condenser coils. These findings offer insights into optimizing a slinger ring design for improved condensate dispersion. Future research should explore airflow variations and alternative slinger ring configurations to enhance WAC performance.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-03-24
DOI
https://doi.org/10.3390/en18071622
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated CFD and Experimental Analysis on Slinger Ring Condensate Discharge Mechanism for Energy-Efficient Window Air Conditioners

Hyun Sik Yoon, Chia‐Chan Chang, Adarsh R. Nair, Man Yeong Ha et al.
1 citations
Energies
Refrigeration and Air Conditioning Technologies
0.71
article

Integrated CFD and Experimental Analysis on Slinger Ring Condensate Discharge Mechanism for Energy-Efficient Window Air Conditioners

Hyun Sik Yoon, Chia‐Chan Chang, Adarsh R. Nair, Man Yeong Ha, Sang‐Bum Hong
article en
1 citations

Abstract

As global demand for energy-efficient cooling technologies grows, optimizing window air conditioners (WACs) is crucial. This study integrates computational fluid dynamics (CFD) and experimental fluid dynamics (EFD) to analyze condensate transport induced by the slinger ring in a WAC system. To investigate condensate behavior, the WAC domain is divided into six regions based on the slinger ring’s rotational direction and impact. In the initial impact zone, large liquid structures adhere to the slinger ring before breaking into ligaments. In the upward transport region, condensate films rise along the wall due to centrifugal forces, forming short ligaments. In the rebound region, condensate impacts the top surface and transitions into droplets. In the accumulation zone, droplet coalescence occurs in a confined space, leading to localized mass buildup. In the dispersion region, condensate spreads widely due to increased rotational speed. In the splash zone, splashing and wave-like structures form near the reservoir surface. A newly identified mechanism of condensate mass discharge shows that mass ejection is concentrated in four key regions near the condenser coils. These findings offer insights into optimizing a slinger ring design for improved condensate dispersion. Future research should explore airflow variations and alternative slinger ring configurations to enhance WAC performance.

EnergiesVol. 18(7)
Pusan National University (KR)
Openalex Percentile: Top 35%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integrated CFD and Experimental Analysis on Slinger Ring Condensate Discharge Mechanism for Energy-Efficient Window Air Conditioners — Hyun Sik Yoon, Chia‐Chan Chang, et al. · Energies (2025) | TGRS Research Map | TGRS