Machine learning-based method to detect capillary stalling using optical coherence tomography

Capillary stalling has emerged as an important mechanistic and potential therapeutic target in mouse models of several neurological disorders. Time-series optical coherence tomography angiography (OCTA) has been used to rapidly detect capillary stalling over hundreds of capillaries in 3D and can be used to study this phenomenon in a research setting. However, existing methods for quantifying capillary stalls are labor-intensive, prone to errors, and may be limited by their reliance on 2D representations of inherently 3D data. To address these limitations, we developed a computational approach based on a support vector machine (SVM) trained on engineered features pertaining to OCTA time-series data. When evaluated with 4-fold cross-validation, the final classifier achieved a receiver operating characteristic (ROC) area under the curve (AUC) of .978 (baseline: 0.5) and a precision-recall (PR) AUC of .700 (baseline: 0.013). It also reduced the amount of time required to annotate from 1 hour to 22 minutes per dataset and detected an average of 8.1 stalling segments in each dataset that were missed by expert annotations, which amounted to 26% of all stalling segments. To demonstrate the utility of our tool, we measured the morphological properties of capillaries and found that stalling segments are significantly smaller in diameter, more tortuous, and longer than non-stalling segments. These findings highlight the algorithm's potential to uncover morphological patterns associated with stalling and facilitate comparative studies across experimental conditions. To support further research, the tool is freely available as open-source software for use by the scientific community.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-03-24
DOI
https://doi.org/10.1364/boe.558490
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning-based method to detect capillary stalling using optical coherence tomography

Rockwell P. Tang, Sabina Ştefan, Jong‐Hwan Lee, David A. Boas et al.
Biomedical Optics Express
Optical Coherence Tomography Applications
article

Machine learning-based method to detect capillary stalling using optical coherence tomography

Rockwell P. Tang, Sabina Ştefan, Jong‐Hwan Lee, David A. Boas, Gülce Küreli, Sreekanth Kura, John Jiang, E. Long, Joshua Assi
article en

Abstract

Capillary stalling has emerged as an important mechanistic and potential therapeutic target in mouse models of several neurological disorders. Time-series optical coherence tomography angiography (OCTA) has been used to rapidly detect capillary stalling over hundreds of capillaries in 3D and can be used to study this phenomenon in a research setting. However, existing methods for quantifying capillary stalls are labor-intensive, prone to errors, and may be limited by their reliance on 2D representations of inherently 3D data. To address these limitations, we developed a computational approach based on a support vector machine (SVM) trained on engineered features pertaining to OCTA time-series data. When evaluated with 4-fold cross-validation, the final classifier achieved a receiver operating characteristic (ROC) area under the curve (AUC) of .978 (baseline: 0.5) and a precision-recall (PR) AUC of .700 (baseline: 0.013). It also reduced the amount of time required to annotate from 1 hour to 22 minutes per dataset and detected an average of 8.1 stalling segments in each dataset that were missed by expert annotations, which amounted to 26% of all stalling segments. To demonstrate the utility of our tool, we measured the morphological properties of capillaries and found that stalling segments are significantly smaller in diameter, more tortuous, and longer than non-stalling segments. These findings highlight the algorithm's potential to uncover morphological patterns associated with stalling and facilitate comparative studies across experimental conditions. To support further research, the tool is freely available as open-source software for use by the scientific community.

Biomedical Optics ExpressVol. 16(5)
Allen Institute for Brain Science (US), John Brown University (US), Brown University (US), Dana-Farber Cancer Institute (US)
Affordable and clean energy
Openalex Percentile: Top 95%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.