Acute Hemodynamic Changes Induced by Cardiac Contractility Modulation Evaluated Using the NICaS® System: A Pilot Study

<b>Background/Objectives</b>: Heart failure (HF) with reduced ejection fraction remains a significant global health challenge despite advances in medical therapy. Cardiac contractility modulation (CCM) is a promising treatment for symptomatic HF patients who are ineligible for cardiac resynchronization therapy (CRT). Non-invasive methods to assess the acute hemodynamic effects of CCM are critical to optimize care and guide treatment. This study aimed to evaluate the acute impact of CCM on stroke volume (SV) and total peripheral resistance index (TPRI) using the non-invasive bioimpedance-based system (NICaS<sup>®</sup>). <b>Methods</b>: Eight HF patients (median age: 64.6 years, median left ejection fraction (LVEF): 34.5%) underwent implantation of the Optimizer Smart Mini CCM device. Hemodynamic parameters, including SV and TPRI, were measured using NICaS<sup>®</sup> at baseline (pre-implantation) and at 1 week, 1 month, and 3 months post-implantation. Measurements were repeated eight times per session and analyzed using non-parametric statistical tests, including the Kruskal-Wallis test, Mann-Whitney test, and Kolmogorov-Smirnov test. <b>Results</b>: Median SV increased significantly from 40.02 mL (interquartile range (IQR): 32.62-78.16 mL) at baseline to 69.83 mL (IQR: 58.63-86.36 mL) at 3 months (<i>p</i> < 0.0001). Median TPRI decreased significantly from 2537 dn s/cm<sup>5</sup> m<sup>2</sup> (IQR: 1807-3084 dn s/cm<sup>5</sup> m<sup>2</sup>) to 1307 dn s/cm<sup>5</sup> m<sup>2</sup> (IQR: 1119-1665 dn s/cm<sup>5</sup> m<sup>2</sup>) over the same period (<i>p</i> < 0.0001). CCM therapy significantly improved SV and reduced TPRI in HF patients within three months of implantation. <b>Conclusions</b>: NICaS<sup>®</sup> provided a reliable, non-invasive tool for monitoring these acute hemodynamic changes, supporting its use in clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-22
DOI
https://doi.org/10.3390/jcm14072172
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acute Hemodynamic Changes Induced by Cardiac Contractility Modulation Evaluated Using the NICaS® System: A Pilot Study

Silvana De Bonis, Anna Lucia Cavaliere, Andrea Madeo, Giovanni Bisignani
1 citations
Journal of Clinical Medicine
Cardiac pacing and defibrillation studies
1.39
article

Acute Hemodynamic Changes Induced by Cardiac Contractility Modulation Evaluated Using the NICaS® System: A Pilot Study

Silvana De Bonis, Anna Lucia Cavaliere, Andrea Madeo, Giovanni Bisignani
article en
1 citations

Abstract

<b>Background/Objectives</b>: Heart failure (HF) with reduced ejection fraction remains a significant global health challenge despite advances in medical therapy. Cardiac contractility modulation (CCM) is a promising treatment for symptomatic HF patients who are ineligible for cardiac resynchronization therapy (CRT). Non-invasive methods to assess the acute hemodynamic effects of CCM are critical to optimize care and guide treatment. This study aimed to evaluate the acute impact of CCM on stroke volume (SV) and total peripheral resistance index (TPRI) using the non-invasive bioimpedance-based system (NICaS<sup>®</sup>). <b>Methods</b>: Eight HF patients (median age: 64.6 years, median left ejection fraction (LVEF): 34.5%) underwent implantation of the Optimizer Smart Mini CCM device. Hemodynamic parameters, including SV and TPRI, were measured using NICaS<sup>®</sup> at baseline (pre-implantation) and at 1 week, 1 month, and 3 months post-implantation. Measurements were repeated eight times per session and analyzed using non-parametric statistical tests, including the Kruskal-Wallis test, Mann-Whitney test, and Kolmogorov-Smirnov test. <b>Results</b>: Median SV increased significantly from 40.02 mL (interquartile range (IQR): 32.62-78.16 mL) at baseline to 69.83 mL (IQR: 58.63-86.36 mL) at 3 months (<i>p</i> < 0.0001). Median TPRI decreased significantly from 2537 dn s/cm<sup>5</sup> m<sup>2</sup> (IQR: 1807-3084 dn s/cm<sup>5</sup> m<sup>2</sup>) to 1307 dn s/cm<sup>5</sup> m<sup>2</sup> (IQR: 1119-1665 dn s/cm<sup>5</sup> m<sup>2</sup>) over the same period (<i>p</i> < 0.0001). CCM therapy significantly improved SV and reduced TPRI in HF patients within three months of implantation. <b>Conclusions</b>: NICaS<sup>®</sup> provided a reliable, non-invasive tool for monitoring these acute hemodynamic changes, supporting its use in clinical practice.

Journal of Clinical MedicineVol. 14(7)
Ferrari (Italy) (IT)
Openalex Percentile: Top 21%
Cardiac pacing and defibrillation studies
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Acute Hemodynamic Changes Induced by Cardiac Contractility Modulation Evaluated Using the NICaS® System: A Pilot Study — Silvana De Bonis, Anna Lucia Cavaliere, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS