Comparison of automated systems using liquid microdilution for the determination of colistin resistance in Klebsiella pneumoniae strains

Objective: In the detection of colistin resistance in Klebsiella pneumoniae strains with multidrug resistance, automated systems give more erroneous results than the gold standard method, the liquid microdilution method.Comparative studies on the correct detection of colistin resistance by automated systems are limited in the literature.In this study; it is aimed to compare Vitek2 Compact and Phoenix automated systems by using liquid microdilution method in the determination of colistin susceptibility in K. pneumoniae strains isolated from various clinical specimens over a three-year period.Methods: Identification of K. pneumoniae strains was performed using conventional microbiological methods and automated bacterial identification systems which are Vitek2 (bioMrieux, MarcyL'Etoile, France) and Phoenix (Becton dickinson, M50 , USA).Antibiotic susceptibility tests were also performed with the same devices.Colistin sensitivity was determined Makale Dili "Trke"/

Authors

Publication Details

Journal
Turkish Bulletin of Hygiene and Experimental Biology
Published
2025-01-01
DOI
https://doi.org/10.5505/turkhijyen.2025.48243
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of automated systems using liquid microdilution for the determination of colistin resistance in Klebsiella pneumoniae strains

Selin Uğraklı, Metin DOĞAN, Burak Ezer, Zekeriya TAŞKIN et al.
Turkish Bulletin of Hygiene and Experimental Biology
Bacterial Identification and Susceptibility Testing
article

Comparison of automated systems using liquid microdilution for the determination of colistin resistance in Klebsiella pneumoniae strains

Selin Uğraklı, Metin DOĞAN, Burak Ezer, Zekeriya TAŞKIN, Kadir KABA
article en

Abstract

Objective: In the detection of colistin resistance in Klebsiella pneumoniae strains with multidrug resistance, automated systems give more erroneous results than the gold standard method, the liquid microdilution method.Comparative studies on the correct detection of colistin resistance by automated systems are limited in the literature.In this study; it is aimed to compare Vitek2 Compact and Phoenix automated systems by using liquid microdilution method in the determination of colistin susceptibility in K. pneumoniae strains isolated from various clinical specimens over a three-year period.Methods: Identification of K. pneumoniae strains was performed using conventional microbiological methods and automated bacterial identification systems which are Vitek2 (bioMrieux, MarcyL'Etoile, France) and Phoenix (Becton dickinson, M50 , USA).Antibiotic susceptibility tests were also performed with the same devices.Colistin sensitivity was determined Makale Dili "Trke"/

Turkish Bulletin of Hygiene and Experimental BiologyVol. 82(1)
Openalex Percentile: Top 93%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.