Effect of valve regulation on the operating state of a CO2 two-phase thermosyphon loop

During the operation of two-phase thermosyphon loops (TPTLs), different types of oscillations may occur, affecting their safety and performance. Although existing research has preliminarily explored the use of valve regulation to eliminate oscillatory operations in TPTLs, the effects of valves on different types of oscillations have not been verified. In this study, valve regulation was applied to two types of oscillation in a CO 2 TPTL. The distinct effects of the valve on each type of oscillation were analyzed in conjunction with their respective mechanisms through experiment. For natural circulation oscillations, valve regulation can effectively suppress fluctuations within the loop. When the valve opening ( θ ) reduced from 100 % to 75 %, the TPTL transitioned from oscillatory to stable operation. However, the thermal performance of the TPTL remained nearly unaffected. For geyser boiling, valve regulation cannot alter the oscillatory operating state within the loop. Even when the θ was reduced from 100 % to 25 %, the TPTL remained in an oscillatory operating state. The results provide a deeper understanding of the influencing mechanisms of valve regulation and offer insights into the active regulation of TPTLs.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-03-24
DOI
https://doi.org/10.1016/j.csite.2025.106055
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of valve regulation on the operating state of a CO2 two-phase thermosyphon loop

Wencheng Wang, Zhen Tong, Zekun Han, Songtao Hu et al.
1 citations
Case Studies in Thermal Engineering
Heat Transfer and Boiling Studies
0.71
article

Effect of valve regulation on the operating state of a CO2 two-phase thermosyphon loop

Wencheng Wang, Zhen Tong, Zekun Han, Songtao Hu, Peng Wang, Huili Yu
article en
1 citations

Abstract

During the operation of two-phase thermosyphon loops (TPTLs), different types of oscillations may occur, affecting their safety and performance. Although existing research has preliminarily explored the use of valve regulation to eliminate oscillatory operations in TPTLs, the effects of valves on different types of oscillations have not been verified. In this study, valve regulation was applied to two types of oscillation in a CO 2 TPTL. The distinct effects of the valve on each type of oscillation were analyzed in conjunction with their respective mechanisms through experiment. For natural circulation oscillations, valve regulation can effectively suppress fluctuations within the loop. When the valve opening ( θ ) reduced from 100 % to 75 %, the TPTL transitioned from oscillatory to stable operation. However, the thermal performance of the TPTL remained nearly unaffected. For geyser boiling, valve regulation cannot alter the oscillatory operating state within the loop. Even when the θ was reduced from 100 % to 25 %, the TPTL remained in an oscillatory operating state. The results provide a deeper understanding of the influencing mechanisms of valve regulation and offer insights into the active regulation of TPTLs.

Case Studies in Thermal EngineeringVol. 69
Qingdao University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province
Affordable and clean energy
Openalex Percentile: Top 35%
Heat Transfer and Boiling Studies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of valve regulation on the operating state of a CO2 two-phase thermosyphon loop — Wencheng Wang, Zhen Tong, et al. · Case Studies in Thermal Engineering (2025) | TGRS Research Map | TGRS