Enhancing Radiation Safety and Justification of Imaging in Pediatric Chest Radiography: Insights from a Tertiary Hospital in Tanzania.

Objectives: This study focuses on the critical "Justification and Optimization" principles of radiation protection during pediatric chest X-ray (CXR) examinations, the most common radiographic procedure, to reduce unnecessary ionizing radiation exposure and enhance safety protocols. Given that children are particularly vulnerable to the long-term biological effects of ionizing radiation, such as cancer and hereditary conditions, this research evaluates the application of these principles at a tertiary hospital in Tanzania. Methods: A hospital-based, cross-sectional study was conducted on 320 pediatric patients who underwent AP/PA CXR examinations over six months. The "justification" of CXR requests was assessed by comparing them with the "European Radiology and Nuclear Medicine Pediatric Imaging Referral Guideline." The "optimization" of radiation protection was evaluated using six radiographic criteria: X-ray beam projection, collimation, rotation, console exposure parameters, repeated examinations, and the use of thyroid and abdominopelvic shielding. The study used frequencies, percentages, measures of central tendencies, Pearson Chi-square test, logistic regression, t-tests, and ANOVA for data analysis, with significance set at p<0.05, all conducted using SPSS version 29.0. Results: Among the 320 participants, 57.2% were male, with the majority aged 1-5 years (41.9%), and a mean age of 3.2 years ± 1.6. Clinically unjustified CXR requests accounted for 36.6%, predominantly from outpatient departments (82.9%). Optimization failures were observed in AP projection (79.7%), collimation (69.7%), and rotation (63.8%) of the exams, particularly in children under five years old. Additionally, 11.6% of the CXR exams were unnecessarily repeated, and 36.9% did not meet optimal console exposure settings. No thyroid or abdominopelvic shielding was used in any examination. Conclusion: The findings reveal that approximately one-third of pediatric CXR exams were unjustified, and many were conducted using suboptimal techniques, highlighting the urgent need to strengthen the implementation of justification and optimization principles in pediatric radiography.

Authors

Institutions

Publication Details

Journal
Saudi Journal of Radiology
Published
2024-12-10
DOI
https://doi.org/10.55038/yb562b26
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Radiation Safety and Justification of Imaging in Pediatric Chest Radiography: Insights from a Tertiary Hospital in Tanzania.

Zuhura Nkrumbih, Yasser H. Hadi, Frederick Lyimo, Jumaa Dachi Kisukari et al.
1 links
Saudi Journal of Radiology
Radiation Dose and Imaging
article

Enhancing Radiation Safety and Justification of Imaging in Pediatric Chest Radiography: Insights from a Tertiary Hospital in Tanzania.

Zuhura Nkrumbih, Yasser H. Hadi, Frederick Lyimo, Jumaa Dachi Kisukari, Victor Mhezi
article en

Abstract

Objectives: This study focuses on the critical "Justification and Optimization" principles of radiation protection during pediatric chest X-ray (CXR) examinations, the most common radiographic procedure, to reduce unnecessary ionizing radiation exposure and enhance safety protocols. Given that children are particularly vulnerable to the long-term biological effects of ionizing radiation, such as cancer and hereditary conditions, this research evaluates the application of these principles at a tertiary hospital in Tanzania. Methods: A hospital-based, cross-sectional study was conducted on 320 pediatric patients who underwent AP/PA CXR examinations over six months. The "justification" of CXR requests was assessed by comparing them with the "European Radiology and Nuclear Medicine Pediatric Imaging Referral Guideline." The "optimization" of radiation protection was evaluated using six radiographic criteria: X-ray beam projection, collimation, rotation, console exposure parameters, repeated examinations, and the use of thyroid and abdominopelvic shielding. The study used frequencies, percentages, measures of central tendencies, Pearson Chi-square test, logistic regression, t-tests, and ANOVA for data analysis, with significance set at p<0.05, all conducted using SPSS version 29.0. Results: Among the 320 participants, 57.2% were male, with the majority aged 1-5 years (41.9%), and a mean age of 3.2 years ± 1.6. Clinically unjustified CXR requests accounted for 36.6%, predominantly from outpatient departments (82.9%). Optimization failures were observed in AP projection (79.7%), collimation (69.7%), and rotation (63.8%) of the exams, particularly in children under five years old. Additionally, 11.6% of the CXR exams were unnecessarily repeated, and 36.9% did not meet optimal console exposure settings. No thyroid or abdominopelvic shielding was used in any examination. Conclusion: The findings reveal that approximately one-third of pediatric CXR exams were unjustified, and many were conducted using suboptimal techniques, highlighting the urgent need to strengthen the implementation of justification and optimization principles in pediatric radiography.

Saudi Journal of RadiologyVol. 3(2)
Muhimbili University of Health and Allied Sciences (TZ), King Abdullah Medical City (SA), Ocean Road Cancer Institute (TZ)
Muhimbili University of Health and Allied Sciences
Openalex Percentile: Top 56%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.