Study of Tacrolimus Calibrator and Reagent Matrix Effect

A specific drug concentration in the blood must be maintained for tacrolimus, which controls immune rejection in organ transplant patients. Therefore, monitoring it through accurate tests is important to confirm this level. This paper reports a case in which the quality control results differed according to the calibrator and reagent in the tacrolimus test. This laboratory performs a tacrolimus (FK-506) test using the Alinity I system. Multichem WBT was used as a quality control material. Quality control materials were installed in the equipment within 30 minutes of manual pretreatment. A comparison of the quality control results of calibrator lot number 46248FP00 and reagent lot number 46243FP00 with calibrator lot number 46248FP00 and reagent lot number 50450FP00 revealed a 16% difference in values between calibrator lot number 46248FP00 and reagent lot number 50450FP00. These results were attributed to differences between the reagents and calibration materials. Hence, manufacturers and laboratories need to prepare for this.

Authors

Publication Details

Journal
Korean Journal of Clinical Laboratory Science
Published
2025-03-24
DOI
https://doi.org/10.15324/kjcls.2025.57.1.88
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Tacrolimus Calibrator and Reagent Matrix Effect

H C Jung
Korean Journal of Clinical Laboratory Science
Renal Transplantation Outcomes and Treatments
article

Study of Tacrolimus Calibrator and Reagent Matrix Effect

H C Jung
article en

Abstract

A specific drug concentration in the blood must be maintained for tacrolimus, which controls immune rejection in organ transplant patients. Therefore, monitoring it through accurate tests is important to confirm this level. This paper reports a case in which the quality control results differed according to the calibrator and reagent in the tacrolimus test. This laboratory performs a tacrolimus (FK-506) test using the Alinity I system. Multichem WBT was used as a quality control material. Quality control materials were installed in the equipment within 30 minutes of manual pretreatment. A comparison of the quality control results of calibrator lot number 46248FP00 and reagent lot number 46243FP00 with calibrator lot number 46248FP00 and reagent lot number 50450FP00 revealed a 16% difference in values between calibrator lot number 46248FP00 and reagent lot number 50450FP00. These results were attributed to differences between the reagents and calibration materials. Hence, manufacturers and laboratories need to prepare for this.

Korean Journal of Clinical Laboratory ScienceVol. 57(1)
Openalex Percentile: Top 91%
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.