A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples

A label-free electrochemical immunosensor based on the zeolitic imidazolate framework-8 (ZIF8)/bismuth ferrite (BFO) nanocomposite was fabricated for the specific and sensitive quantification of prostate-specific antigen (PSA). The ZIF8-BFO material not only increases the surface area effectively but also enhances the catalytic capability of the electrode through a dual amplification strategy, leading to the improved sensitivity of the probe for PSA recognition. A thin layer of l-cysteine was used for two reasons: providing a scaffold for the next functionalization and reducing the fouling of plasma ingredients on the surface of the probe. The mechanical and spectroscopic properties of the produced nanomaterials were characterized using different techniques such as field emission scanning electron microscopy (FESEM), x-ray diffraction (XRD), atomic force microscopy (AFM), the Fourier transform infrared (FTIR), and dynamic light scattering (DLS)/Zeta analyzer. The electroanalytical properties of the probe were studied using square-wave voltammetry (SWV) and cyclic voltammetry (CV). The signal of the probe decreased proportionally with increasing PSA concentration in the 100.0 pg/mL-15.0 ng/mL range, with a limit of detection (LOD) of 85 pg/mL. The proposed platform has been successfully employed to measure PSA levels in human serum samples with acceptable accuracy. The capability of the probe was evaluated in detecting PSA in patient's serum samples, with results compared to those obtained from the gold standard enzyme-linked immunosorbent assay (ELISA). The results suggested that the ZIF8-BFO material-based probe could be used as a promising method for detecting PSA and tracing therapy progression in clinics.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2025-03-23
DOI
https://doi.org/10.1002/bab.2752
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples

Abul Hussam, Ahmed Hjazi, Zaman Abdalhussein Ibadi Alaridhee, Ameer H. Al‐Rubaye et al.
2 citations
Biotechnology and Applied Biochemistry
Advanced biosensing and bioanalysis techniques
1.61
article

A Low‐Fouling Electrochemical Immunosensor Based On Metal–Organic Framework and Ternary Metal Oxide Nanomaterials Using Dual Signal Amplification Strategy for Sensitive Detection of Prostate‐Specific Antigen (PSA) in Patient Samples

Abul Hussam, Ahmed Hjazi, Zaman Abdalhussein Ibadi Alaridhee, Ameer H. Al‐Rubaye, Marwah Suliman Maashi, Majid Sakhi Jabir, Hasan Sh. Majdi, Nizomiddin Juraev, Faeza H. Zankanah, Mosleh Mohammad Abomughaid
article en
2 citations

Abstract

A label-free electrochemical immunosensor based on the zeolitic imidazolate framework-8 (ZIF8)/bismuth ferrite (BFO) nanocomposite was fabricated for the specific and sensitive quantification of prostate-specific antigen (PSA). The ZIF8-BFO material not only increases the surface area effectively but also enhances the catalytic capability of the electrode through a dual amplification strategy, leading to the improved sensitivity of the probe for PSA recognition. A thin layer of l-cysteine was used for two reasons: providing a scaffold for the next functionalization and reducing the fouling of plasma ingredients on the surface of the probe. The mechanical and spectroscopic properties of the produced nanomaterials were characterized using different techniques such as field emission scanning electron microscopy (FESEM), x-ray diffraction (XRD), atomic force microscopy (AFM), the Fourier transform infrared (FTIR), and dynamic light scattering (DLS)/Zeta analyzer. The electroanalytical properties of the probe were studied using square-wave voltammetry (SWV) and cyclic voltammetry (CV). The signal of the probe decreased proportionally with increasing PSA concentration in the 100.0 pg/mL-15.0 ng/mL range, with a limit of detection (LOD) of 85 pg/mL. The proposed platform has been successfully employed to measure PSA levels in human serum samples with acceptable accuracy. The capability of the probe was evaluated in detecting PSA in patient's serum samples, with results compared to those obtained from the gold standard enzyme-linked immunosorbent assay (ELISA). The results suggested that the ZIF8-BFO material-based probe could be used as a promising method for detecting PSA and tracing therapy progression in clinics.

Biotechnology and Applied BiochemistryVol. 72(5)
Prince Sattam Bin Abdulaziz University (SA), University of Technology - Iraq (IQ), King Abdulaziz University (SA), Baghdad Medical City (IQ), University of Alkafeel (IQ), King Abdulaziz Medical City (SA), University Of Fallujah (IQ), University of Misan (IQ), University of Bisha (SA), King Fahad Hospital Jeddah (SA), National Pedagogical University of Uzbekistan named after Nizami (UZ), New Uzbekistan University (UZ), National University of Uzbekistan (UZ)
Prince Sattam bin Abdulaziz University
Openalex Percentile: Top 18%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.