Study of F-wave Components in a Control Population of Young Adults

Introduction The F-wave represents a delayed muscular response that occurs as a result of the antidromic activation of one or a few motoneurons ensuing the electrical stimulation of a peripheral nerve. F-wave response has various parameters, yet the primary application of F-waves is presently confined to latency measurement, with a particular emphasis on F-wave minimum latency. Our goal is to report F-wave data in a population of young healthy individuals, encompassing rarely examined components including F-wave/M-wave amplitude (F/M ratio), duration, chronodispersion, and persistence in both upper and lower extremity nerves. Methods F-response components were recorded from median, ulnar, tibial, and peroneal nerves in 100 healthy volunteers in the age group of 18-40 years. Linear regression analysis was conducted for the correlation of F-wave parameters with height and age. Gender comparison (unpaired t-test) and side-to-side comparison (paired t-test) were performed. A p-value of <0.05 was considered statistically significant. Results R2 values for the relationship of F-wave minimum latency with height for median, ulnar, tibial, and peroneal nerves were 0.755, 0.761, 0.739, and 0.650, respectively, suggesting a strong direct relation. F-wave minimum latency (mean value) increased by about 0.27±0.7 ms on the right side (as compared to the left) with statistical significance (p<0.001) (paired t-test) for the F-wave median study. Male participants had increased F-wave minimum latency: p<0.0001 and p<0.01 (unpaired t-test) for median (right and left sides, respectively) while p<0.05 for ulnar, tibial, and peroneal nerves (both sides). No other F-wave components exhibited significant variation in height, gender, and age. Conclusion The current research has established normal values for the various F-response components, including F-wave latencies, F-wave duration, F/M amplitude ratio, chronodispersion, and persistence in the young adult age group. Side difference reference values have also been established. A strong influence of height should be borne in mind during F-wave interpretation. Reference values for the relatively scarcely studied F-wave component including F/M amplitude ratio, F-wave duration, F-wave persistence, and chronodispersion can be helpful in diversifying the clinical applicability of the F-response study.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-23
DOI
https://doi.org/10.7759/cureus.81059
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of F-wave Components in a Control Population of Young Adults

Sangeeta Gupta, Ramji Singh
Cureus
Muscle activation and electromyography studies
article

Study of F-wave Components in a Control Population of Young Adults

Sangeeta Gupta, Ramji Singh
article en

Abstract

Introduction The F-wave represents a delayed muscular response that occurs as a result of the antidromic activation of one or a few motoneurons ensuing the electrical stimulation of a peripheral nerve. F-wave response has various parameters, yet the primary application of F-waves is presently confined to latency measurement, with a particular emphasis on F-wave minimum latency. Our goal is to report F-wave data in a population of young healthy individuals, encompassing rarely examined components including F-wave/M-wave amplitude (F/M ratio), duration, chronodispersion, and persistence in both upper and lower extremity nerves. Methods F-response components were recorded from median, ulnar, tibial, and peroneal nerves in 100 healthy volunteers in the age group of 18-40 years. Linear regression analysis was conducted for the correlation of F-wave parameters with height and age. Gender comparison (unpaired t-test) and side-to-side comparison (paired t-test) were performed. A p-value of <0.05 was considered statistically significant. Results R2 values for the relationship of F-wave minimum latency with height for median, ulnar, tibial, and peroneal nerves were 0.755, 0.761, 0.739, and 0.650, respectively, suggesting a strong direct relation. F-wave minimum latency (mean value) increased by about 0.27±0.7 ms on the right side (as compared to the left) with statistical significance (p<0.001) (paired t-test) for the F-wave median study. Male participants had increased F-wave minimum latency: p<0.0001 and p<0.01 (unpaired t-test) for median (right and left sides, respectively) while p<0.05 for ulnar, tibial, and peroneal nerves (both sides). No other F-wave components exhibited significant variation in height, gender, and age. Conclusion The current research has established normal values for the various F-response components, including F-wave latencies, F-wave duration, F/M amplitude ratio, chronodispersion, and persistence in the young adult age group. Side difference reference values have also been established. A strong influence of height should be borne in mind during F-wave interpretation. Reference values for the relatively scarcely studied F-wave component including F/M amplitude ratio, F-wave duration, F-wave persistence, and chronodispersion can be helpful in diversifying the clinical applicability of the F-response study.

CureusVol. 17(3)
Baba Raghav Das Medical College (IN), All India Institute of Medical Sciences (IN), University of Kalyani (IN)
Openalex Percentile: Top 95%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.