A rare case of hemorrhage from spontaneous disconnection of super-HeRO adapter and early-cannulation graft: A case report

To overcome the limitations of central venous occlusion or stenosis (CVO) in complex chronic hemodialysis patients, the Hemodialysis Reliable Outflow (HeRO) vascular access graft was created as an alternative means of vascular access that bypasses the CVO and provides an additional upper extremity access option. The super-HeRO adapter was created to allow for the use of early cannulation grafts in the HeRO graft thereby enabling early cannulation and reducing tunneled dialysis catheter dependence time. Some complications have been previously reported for the traditional HeRO and the modified HeRO grafts. We report, a complication of spontaneous and delayed dehiscence/disconnection of the arterial graft from the venous outflow of a modified HeRO graft leading to massive hemorrhage. This complication has never been reported in literature. Our patient suffered this complication 4 weeks after implantation without any known inciting events. While it is unclear why this complication occurred, we must consider potential factors such as technical error of securing the arterial graft to the super-HeRO adapter coupler. Management involved immediate graft ligation given that the patient was in extremis upon presentation. Although deviations from instructions for use (IFU) are common in vascular surgery, particularly in endovascular cases for dialysis access, peripheral arterial disease, and aortic aneurysms, we recommend strict adherence to IFU for HeRO graft placement. Although rare, the sequalae of coupler dehiscence can be catastrophic and even fatal. Despite this complication, modification of the HeRO graft with the super-HeRO adapter remains a safe and feasible approach for establishing upper extremity dialysis access in complex ESRD patients with central venous pathology; we strongly caution that these cases should be performed in strict adherence with IFU using a 6 mm graft and the support seal system.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2025-03-23
DOI
https://doi.org/10.1177/11297298251326970
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A rare case of hemorrhage from spontaneous disconnection of super-HeRO adapter and early-cannulation graft: A case report

Christina L. Cui, Kevin W. Southerland, Anthony Eze, Akachukwu N Eze et al.
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

A rare case of hemorrhage from spontaneous disconnection of super-HeRO adapter and early-cannulation graft: A case report

Christina L. Cui, Kevin W. Southerland, Anthony Eze, Akachukwu N Eze, Young Kim, Amika Ekanem
article en

Abstract

To overcome the limitations of central venous occlusion or stenosis (CVO) in complex chronic hemodialysis patients, the Hemodialysis Reliable Outflow (HeRO) vascular access graft was created as an alternative means of vascular access that bypasses the CVO and provides an additional upper extremity access option. The super-HeRO adapter was created to allow for the use of early cannulation grafts in the HeRO graft thereby enabling early cannulation and reducing tunneled dialysis catheter dependence time. Some complications have been previously reported for the traditional HeRO and the modified HeRO grafts. We report, a complication of spontaneous and delayed dehiscence/disconnection of the arterial graft from the venous outflow of a modified HeRO graft leading to massive hemorrhage. This complication has never been reported in literature. Our patient suffered this complication 4 weeks after implantation without any known inciting events. While it is unclear why this complication occurred, we must consider potential factors such as technical error of securing the arterial graft to the super-HeRO adapter coupler. Management involved immediate graft ligation given that the patient was in extremis upon presentation. Although deviations from instructions for use (IFU) are common in vascular surgery, particularly in endovascular cases for dialysis access, peripheral arterial disease, and aortic aneurysms, we recommend strict adherence to IFU for HeRO graft placement. Although rare, the sequalae of coupler dehiscence can be catastrophic and even fatal. Despite this complication, modification of the HeRO graft with the super-HeRO adapter remains a safe and feasible approach for establishing upper extremity dialysis access in complex ESRD patients with central venous pathology; we strongly caution that these cases should be performed in strict adherence with IFU using a 6 mm graft and the support seal system.

The Journal of Vascular AccessVol. 27(1)
Howard University (US), Duke University (US), Duke Institute for Health Innovation (US)
Openalex Percentile: Top 91%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.