Direct electron transfer chemistry of redox‐active enzymes: applications in biosensor development

Abstract The direct electron transfer (DET) process, which does not require a mediator, is highly advantageous and holds significant potential for application in biosensors. Enzyme‐based biosensors are simple, cost‐efficient, and easy to use. This review highlights key enzymes with redox‐active sites that are suitable for DET processes using various modified electrodes and their applications in biosensors. The review discusses enzyme classification, distinguishing between single‐cofactor and multi‐cofactor enzymes according to their number of prosthetic groups, with a focus on internal electron transfer processes and the role of redox‐active centers. Methods for enzyme immobilization on electrodes are explored with an emphasis on their impact on electron transfer rates in biosensors. A comparison of sensitivity, electron transfer rates, and the linear detection range of molecules (e.g., glucose and lactose) is provided to illustrate the impact of different immobilization techniques on biosensor performance.

Authors

Institutions

Publication Details

Journal
Biofuels Bioproducts and Biorefining
Published
2025-03-21
DOI
https://doi.org/10.1002/bbb.2742
Citations
8
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
5.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct electron transfer chemistry of redox‐active enzymes: applications in biosensor development

Muhammad Babar Taj, Suryyia Manzoor, Muhammad Imran Khan, Nosheen Farooq et al.
8 citations
Biofuels Bioproducts and Biorefining
Electrochemical sensors and biosensors
5.84
article

Direct electron transfer chemistry of redox‐active enzymes: applications in biosensor development

Muhammad Babar Taj, Suryyia Manzoor, Muhammad Imran Khan, Nosheen Farooq, Abdallah Shanableh, Fawad Ahmad, Komal Rao, Rafael Luque, Leonid G. Voskressensky, Shafaq Zahid
article en
8 citations

Abstract

Abstract The direct electron transfer (DET) process, which does not require a mediator, is highly advantageous and holds significant potential for application in biosensors. Enzyme‐based biosensors are simple, cost‐efficient, and easy to use. This review highlights key enzymes with redox‐active sites that are suitable for DET processes using various modified electrodes and their applications in biosensors. The review discusses enzyme classification, distinguishing between single‐cofactor and multi‐cofactor enzymes according to their number of prosthetic groups, with a focus on internal electron transfer processes and the role of redox‐active centers. Methods for enzyme immobilization on electrodes are explored with an emphasis on their impact on electron transfer rates in biosensors. A comparison of sensitivity, electron transfer rates, and the linear detection range of molecules (e.g., glucose and lactose) is provided to illustrate the impact of different immobilization techniques on biosensor performance.

Biofuels Bioproducts and BiorefiningVol. 19(3)
Peoples' Friendship University of Russia (RU), Bahauddin Zakariya University (PK), Islamia University of Bahawalpur (PK), University of Wah (PK), Government Sadiq College Women University (PK), University of Sharjah (AE), Universidad Ecotec (EC), Australian University, Kuwait (KW)
RUDN University
Openalex Percentile: Top 4%
Electrochemical sensors and biosensors
5.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.