Capture of Fine Particles by a Multivortex Separator in a Paint Drying Chamber

Paint spraying and drying booths are widely used in various industries. During spraying paint and varnish materials, a significant amount of contaminants—paint mist particles—is generated inside the booth, making their capture an important task. Failure to address this issue may lead to explosive hazards, violations of sanitary and environmental regulations, defects in coated parts, and other negative consequences. Ceiling and floor filters are commonly used for this purpose, but they are typically imported and require regular replacement, usually once a month. Therefore, extending their service life is an urgent task. This paper aims to develop a separation device to extend the service life of floor and ceiling filters in a paint-drying booth and enhance the overall efficiency of fine particle capture. The article presents the design of a multivortex separator and describes its operating principle. The direct application of the multivortex separator in a paint-spraying drying chamber at Kamatek Ltd. is considered. To increase filter longevity, it is proposed to install the separator upstream of either the floor or ceiling filters. The efficiency of the multivortex separator was calculated for two installation configurations within the paint-drying booth. Based on the efficiency calculations, the following conclusions were drawn: when the separator is installed upstream of the floor filters (with an inlet velocity of 0.3 m/s), its efficiency averages 45% for particles sized 1 to 10 µm; when installed upstream of the ceiling filters in the narrow section (with an inlet velocity of 5 m/s), its efficiency averages 88% for particles of the same size range. In practical terms, installing the multivortex separator before the ceiling fine filters is more effective, as it achieves higher efficiency with minimal capital investment.

Authors

Institutions

Publication Details

Journal
Theoretical Foundations of Chemical Engineering
Published
2024-10-01
DOI
https://doi.org/10.1134/s0040579525600421
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capture of Fine Particles by a Multivortex Separator in a Paint Drying Chamber

R. Ya. Bikkulov, А. В. Дмитриев, A. A. Abdullina, V. É. Zinurov
2 links
Theoretical Foundations of Chemical Engineering
Cyclone Separators and Fluid Dynamics
article

Capture of Fine Particles by a Multivortex Separator in a Paint Drying Chamber

R. Ya. Bikkulov, А. В. Дмитриев, A. A. Abdullina, V. É. Zinurov
article en

Abstract

Paint spraying and drying booths are widely used in various industries. During spraying paint and varnish materials, a significant amount of contaminants—paint mist particles—is generated inside the booth, making their capture an important task. Failure to address this issue may lead to explosive hazards, violations of sanitary and environmental regulations, defects in coated parts, and other negative consequences. Ceiling and floor filters are commonly used for this purpose, but they are typically imported and require regular replacement, usually once a month. Therefore, extending their service life is an urgent task. This paper aims to develop a separation device to extend the service life of floor and ceiling filters in a paint-drying booth and enhance the overall efficiency of fine particle capture. The article presents the design of a multivortex separator and describes its operating principle. The direct application of the multivortex separator in a paint-spraying drying chamber at Kamatek Ltd. is considered. To increase filter longevity, it is proposed to install the separator upstream of either the floor or ceiling filters. The efficiency of the multivortex separator was calculated for two installation configurations within the paint-drying booth. Based on the efficiency calculations, the following conclusions were drawn: when the separator is installed upstream of the floor filters (with an inlet velocity of 0.3 m/s), its efficiency averages 45% for particles sized 1 to 10 µm; when installed upstream of the ceiling filters in the narrow section (with an inlet velocity of 5 m/s), its efficiency averages 88% for particles of the same size range. In practical terms, installing the multivortex separator before the ceiling fine filters is more effective, as it achieves higher efficiency with minimal capital investment.

Theoretical Foundations of Chemical EngineeringVol. 58(5)
Kazan State Power Engineering University (RU)
Openalex Percentile: Top 71%
Cyclone Separators and Fluid Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.