Performance evaluation of blood pressure estimation using an RGB-NIR camera

Abstract In this study, we evaluated the performance of blood pressure estimation using an RGB-NIR camera. While non- contact blood pressure measurement methods using RGB images are available, they prove ineffective under low-light conditions. In addition, Visible light penetrates only the skin’s capillaries, failing to reach deeper vessels like arteries. In contrast, near-infrared (NIR) light penetrates deeper into the skin, reaching the arterial layer. By integrating visible and NIR light, we can capture information from both capillaries and arteries. This research proposes a method that combines visible and NIR light to improve blood pressure measurement accuracy. The performance of this combined approach was compared with methods that rely solely on either visible or NIR light. For our experiments, an RGB-NIR camera, capable of simultaneously capturing both RGB and NIR video images, was utilized.

Authors

Institutions

Publication Details

Journal
Artificial Life and Robotics
Published
2025-03-22
DOI
https://doi.org/10.1007/s10015-025-01015-3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of blood pressure estimation using an RGB-NIR camera

Atsushi Kobayashi, Shoji Kawahito, Yuta Hino, Masato Takahashi et al.
Artificial Life and Robotics
Non-Invasive Vital Sign Monitoring
article

Performance evaluation of blood pressure estimation using an RGB-NIR camera

Atsushi Kobayashi, Shoji Kawahito, Yuta Hino, Masato Takahashi, Norimichi Tsumura, Sae Kawasaki, Masaya Kinefuchi
article en

Abstract

Abstract In this study, we evaluated the performance of blood pressure estimation using an RGB-NIR camera. While non- contact blood pressure measurement methods using RGB images are available, they prove ineffective under low-light conditions. In addition, Visible light penetrates only the skin’s capillaries, failing to reach deeper vessels like arteries. In contrast, near-infrared (NIR) light penetrates deeper into the skin, reaching the arterial layer. By integrating visible and NIR light, we can capture information from both capillaries and arteries. This research proposes a method that combines visible and NIR light to improve blood pressure measurement accuracy. The performance of this combined approach was compared with methods that rely solely on either visible or NIR light. For our experiments, an RGB-NIR camera, capable of simultaneously capturing both RGB and NIR video images, was utilized.

Artificial Life and RoboticsVol. 30(3)
Shizuoka University (JP), Chiba University (JP), Toppan (Japan) (JP), Hiroshima University Hospital (JP)
Openalex Percentile: Top 95%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.