Comparison between electrical cardiometry and lung ultrasound in the assessment of lung water in mechanically ventilated patients

Abstract Background Weaning from mechanical ventilation may lead to extubation failure; however, it is advised to wean patients from it earlier to prevent the problems of extended continuous ventilation. Aim of the study This study aimed to compare electrical cardiometry and lung ultrasound in assessing lung water as predictors of weaning failure from invasive mechanical ventilation in patients with preserved ejection fraction heart failure (HFpEF) by measuring thoracic fluid content (TFC) by cardiometry and B lines by ultrasound. Patients and methods This research comprised 70 mechanically ventilated studied cases diagnosed with HFpEF, deemed suitable for weaning, and admitted to the Critical Care Medicine Department at Alexandria Main University Hospital between February 2023 and February 2024. All enrolled patients underwent electrical cardiometry for measuring (TFC) and lung ultrasound to measure B lines. Weaning failure was characterized by the necessity for reintubation within 48 h post-extubation. Patients were segregated into two categories: those who successfully weaned and those who experienced weaning failure. Both groups were then compared based on the study’s outcomes. Results In this study, 52 (74.28%) patients underwent successful weaning, while 18 (25.71) patients underwent failed weaning. B lines were significantly higher in the failed weaning group (18.14 ± 2.35) vs (7.48 ± 2.1) in the successful weaning group. They can significantly predict weaning failure (AUC = 0.878, P value < 0.001). The suggested cut-off value (> 12) showed 72.2% sensitivity and 96.2% specificity. TFC (kΩ −1 ) was significantly higher in the failed weaning group (61.47 ± 5.16) vs (42.50 ± 10.47) in the successful weaning group. TFC was a significant predictor of failed weaning from mechanical ventilation (AUC = 0.950, P value < 0.001). The suggested cut-off value (> 52.8 kΩ −1 ) gave 94% sensitivity and 86% specificity. Conclusion Both B-lines by LUS and TFC by cardiometry are good predictors for weaning failure in HFpEF patients. However, TFC seems to be more sensitive but less specific than LUS.

Authors

Institutions

Publication Details

Journal
Egyptian Journal of Bronchology
Published
2025-03-24
DOI
https://doi.org/10.1186/s43168-024-00360-4
Citations
1
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
1.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between electrical cardiometry and lung ultrasound in the assessment of lung water in mechanically ventilated patients

Mohammed Raafat Elsalamouny, Dina Zidan, Taysseer Mahmoud Zaitoun, Abanoub Kods Azmy Gad-allah
1 citations
Egyptian Journal of Bronchology
Ultrasound in Clinical Applications
1.55
article

Comparison between electrical cardiometry and lung ultrasound in the assessment of lung water in mechanically ventilated patients

Mohammed Raafat Elsalamouny, Dina Zidan, Taysseer Mahmoud Zaitoun, Abanoub Kods Azmy Gad-allah
article en
1 citations

Abstract

Abstract Background Weaning from mechanical ventilation may lead to extubation failure; however, it is advised to wean patients from it earlier to prevent the problems of extended continuous ventilation. Aim of the study This study aimed to compare electrical cardiometry and lung ultrasound in assessing lung water as predictors of weaning failure from invasive mechanical ventilation in patients with preserved ejection fraction heart failure (HFpEF) by measuring thoracic fluid content (TFC) by cardiometry and B lines by ultrasound. Patients and methods This research comprised 70 mechanically ventilated studied cases diagnosed with HFpEF, deemed suitable for weaning, and admitted to the Critical Care Medicine Department at Alexandria Main University Hospital between February 2023 and February 2024. All enrolled patients underwent electrical cardiometry for measuring (TFC) and lung ultrasound to measure B lines. Weaning failure was characterized by the necessity for reintubation within 48 h post-extubation. Patients were segregated into two categories: those who successfully weaned and those who experienced weaning failure. Both groups were then compared based on the study’s outcomes. Results In this study, 52 (74.28%) patients underwent successful weaning, while 18 (25.71) patients underwent failed weaning. B lines were significantly higher in the failed weaning group (18.14 ± 2.35) vs (7.48 ± 2.1) in the successful weaning group. They can significantly predict weaning failure (AUC = 0.878, P value < 0.001). The suggested cut-off value (> 12) showed 72.2% sensitivity and 96.2% specificity. TFC (kΩ −1 ) was significantly higher in the failed weaning group (61.47 ± 5.16) vs (42.50 ± 10.47) in the successful weaning group. TFC was a significant predictor of failed weaning from mechanical ventilation (AUC = 0.950, P value < 0.001). The suggested cut-off value (> 52.8 kΩ −1 ) gave 94% sensitivity and 86% specificity. Conclusion Both B-lines by LUS and TFC by cardiometry are good predictors for weaning failure in HFpEF patients. However, TFC seems to be more sensitive but less specific than LUS.

Egyptian Journal of BronchologyVol. 19(1)
Alexandria University (EG)
Openalex Percentile: Top 22%
Ultrasound in Clinical Applications
1.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.