Increasing the Accuracy of 3D Heart Models Based on Micro-computed Tomography

Micro-CT is an imaging method offering much higher resolution than standard clinical CT, with up to 0.5 m/pixel for the objects 1-2mm.It captures detailed threedimensional images, merging micro and macro anatomy of organs.This study aimed to develop an effective tissue processing protocol for micro-CT of cardiovascular systems.Twenty pig hearts were processed through isolation, perfusion, and flushing with isotonic solution to clear clots.Various immersion and injection reagents, like KI2 and liquid BaSO4, were tested under different conditions.Eight hearts were scanned using GE Nanotom S at AGH's Micro and Nano Tomography Lab, AGH University, Krakow, Poland.The best results came from injecting liquid BaSO4 into coronary arteries at cold temperatures, preventing blockage and leaks.Immersion methods proved less effective.Despite minor gamma corrections in post-processing, this approach yielded optimal imaging.

Authors

Publication Details

Journal
Computing in cardiology
Published
2024-12-01
DOI
https://doi.org/10.22489/cinc.2024.387
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increasing the Accuracy of 3D Heart Models Based on Micro-computed Tomography

Sebastian Wroński, Julianna Dąbrowa, Klaudia Proniewska, Jacek Tarasiuk et al.
Computing in cardiology
Advanced X-ray and CT Imaging
article

Increasing the Accuracy of 3D Heart Models Based on Micro-computed Tomography

Sebastian Wroński, Julianna Dąbrowa, Klaudia Proniewska, Jacek Tarasiuk, Paweł Ozga, Małgorzata Wołek
article en

Abstract

Micro-CT is an imaging method offering much higher resolution than standard clinical CT, with up to 0.5 m/pixel for the objects 1-2mm.It captures detailed threedimensional images, merging micro and macro anatomy of organs.This study aimed to develop an effective tissue processing protocol for micro-CT of cardiovascular systems.Twenty pig hearts were processed through isolation, perfusion, and flushing with isotonic solution to clear clots.Various immersion and injection reagents, like KI2 and liquid BaSO4, were tested under different conditions.Eight hearts were scanned using GE Nanotom S at AGH's Micro and Nano Tomography Lab, AGH University, Krakow, Poland.The best results came from injecting liquid BaSO4 into coronary arteries at cold temperatures, preventing blockage and leaks.Immersion methods proved less effective.Despite minor gamma corrections in post-processing, this approach yielded optimal imaging.

Computing in cardiologyVol. 51
Openalex Percentile: Top 75%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Increasing the Accuracy of 3D Heart Models Based on Micro-computed Tomography — Sebastian Wroński, Julianna Dąbrowa, et al. · Computing in cardiology (2024) | TGRS Research Map | TGRS