Machine learning-assisted techniques for Compton-background discrimination in Broad Energy Germanium (BEGe) detector

Abstract High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad Energy Germanium (BEGe™) detectors. We introduce two machine learning models: an autoencoder-MLP (Multilayer Perceptron) and a Gaussian Mixture Model (GMM). These models differentiate single-site events (SSEs) from multi-site events (MSEs) and train on signal waveforms produced in the detector. The GMM method differs from previous machine learning efforts in that it is fully unsupervised, hence not requiring specific data labelling during the training phase. Being both label-free and simulation-agnostic makes the unsupervised approach particularly advantageous for tasks where realistic, high-fidelity labeling is challenging or where biases introduced by simulated data must be avoided. In our analysis, the full-energy Peak-to-Compton ratio of the $$ ^{137}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>137</mml:mn> </mml:mmultiscripts> </mml:math> Cs, a radionuclide contained in a cryoconite sample, exhibits an improvement from 0.238 in the original spectrum to 0.547 after the ACM data filtering and 0.414 after the GMM data filtering, demonstrating the effectiveness of these methods. The results also showcase an enhancement in the signal-to-background ratio across many regions of interest, enabling the detection of lower concentrations of radionuclides.

Authors

Institutions

Publication Details

Journal
The European Physical Journal C
Published
2025-03-23
DOI
https://doi.org/10.1140/epjc/s10052-025-14042-y
Citations
3
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning-assisted techniques for Compton-background discrimination in Broad Energy Germanium (BEGe) detector

M. Sisti, A. Paonessa, E. Previtali, Andrea Barresi et al.
3 citations
The European Physical Journal C
Medical Imaging Techniques and Applications
4.08
article

Machine learning-assisted techniques for Compton-background discrimination in Broad Energy Germanium (BEGe) detector

M. Sisti, A. Paonessa, E. Previtali, Andrea Barresi, Danilo Labranca, A. Giachero, Giovanni Baccolo, M. Nastasi, Roberto Moretti, D. Chiesa, Marco Picione
article en
3 citations

Abstract

Abstract High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad Energy Germanium (BEGe™) detectors. We introduce two machine learning models: an autoencoder-MLP (Multilayer Perceptron) and a Gaussian Mixture Model (GMM). These models differentiate single-site events (SSEs) from multi-site events (MSEs) and train on signal waveforms produced in the detector. The GMM method differs from previous machine learning efforts in that it is fully unsupervised, hence not requiring specific data labelling during the training phase. Being both label-free and simulation-agnostic makes the unsupervised approach particularly advantageous for tasks where realistic, high-fidelity labeling is challenging or where biases introduced by simulated data must be avoided. In our analysis, the full-energy Peak-to-Compton ratio of the $$ ^{137}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>137</mml:mn> </mml:mmultiscripts> </mml:math> Cs, a radionuclide contained in a cryoconite sample, exhibits an improvement from 0.238 in the original spectrum to 0.547 after the ACM data filtering and 0.414 after the GMM data filtering, demonstrating the effectiveness of these methods. The results also showcase an enhancement in the signal-to-background ratio across many regions of interest, enabling the detection of lower concentrations of radionuclides.

The European Physical Journal CVol. 85(3)
Roma Tre University (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca (IT), University of Milano-Bicocca (IT)
Openalex Percentile: Top 7%
Medical Imaging Techniques and Applications
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.