Nanocomposite-based PCR reactors to enhance thermal rate and fluorescence intensity in hand-held qPCR device

A photonic quantitative polymerase chain reaction (qPCR) has usually implemented a polydimethylsiloxane (PDMS) based disposable inexpensive PCR reactor, worked as the photothermal cycler, to show potential as a point-of-care test (PoCT) for detection nucleic acids. However, the PoCT type photonic qPCR has to overcome the prolonged time for the fabrication of PDMS-based PCR reactors and enable a rapid thermal cycler to shorten diagnosis time with a strong fluorescence intensity. Here, we developed a room-temperature curable titanium dioxide (TiO<sub>2</sub>) nanoparticle dispersed PDMS (TiO<sub>2</sub>-PDMS) nanocomposite to reduce the fabrication time of the PCR reactor which enhanced the speed of photothermal cycles and fluorescence signal intensity of photonic qPCR. The TiO<sub>2</sub>-PDMS nanocomposite was formulated for rapid cross-linking at the room-temperature by introducing an optimized amount of Pt catalyst, resulting in the fabrication of a nanocomposite-based PCR reactor within 8 min at room-temperature. The nanocomposite-based PCR reactor enhanced the heating rate to 18.33 Cº/s and cooling rate to -3.11Cº/s because of the phonon scattering effect of TiO<sub>2</sub> in the reactor and successfully amplified λ-DNA (amplicon size of 100 bp) within 10 min. Finally, we improved the qPCR efficiency by 2 cycle threshold (C<sub>t</sub>) value compared with pristine PDMS reactor and quantified up to 10 copies/µL nucleic acids by fluorescence intensity enhancement resulting from light reflections property of TiO<sub>2</sub>. By using TiO<sub>2</sub>-PDMS nanocomposite-based PCR reactors, the fast and efficient nucleic acid assay was enabled without loss of sensitivity, and it can be practically used in the field of PoCT.

Authors

Institutions

Publication Details

Journal
Journal of Nanobiotechnology
Published
2025-03-23
DOI
https://doi.org/10.1186/s12951-025-03287-0
Citations
7
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
4.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanocomposite-based PCR reactors to enhance thermal rate and fluorescence intensity in hand-held qPCR device

Jiyeon Han, Seongryeong Kim, Kiran Shrestha, Dang Du Nguyen et al.
7 citations
Journal of Nanobiotechnology
Biosensors and Analytical Detection
4.72
article

Nanocomposite-based PCR reactors to enhance thermal rate and fluorescence intensity in hand-held qPCR device

Jiyeon Han, Seongryeong Kim, Kiran Shrestha, Dang Du Nguyen, Gyoujin Cho, Inki Kim, Jinkee Lee, Gabriela Morales Florez, A M Tiara
article en
7 citations

Abstract

A photonic quantitative polymerase chain reaction (qPCR) has usually implemented a polydimethylsiloxane (PDMS) based disposable inexpensive PCR reactor, worked as the photothermal cycler, to show potential as a point-of-care test (PoCT) for detection nucleic acids. However, the PoCT type photonic qPCR has to overcome the prolonged time for the fabrication of PDMS-based PCR reactors and enable a rapid thermal cycler to shorten diagnosis time with a strong fluorescence intensity. Here, we developed a room-temperature curable titanium dioxide (TiO<sub>2</sub>) nanoparticle dispersed PDMS (TiO<sub>2</sub>-PDMS) nanocomposite to reduce the fabrication time of the PCR reactor which enhanced the speed of photothermal cycles and fluorescence signal intensity of photonic qPCR. The TiO<sub>2</sub>-PDMS nanocomposite was formulated for rapid cross-linking at the room-temperature by introducing an optimized amount of Pt catalyst, resulting in the fabrication of a nanocomposite-based PCR reactor within 8 min at room-temperature. The nanocomposite-based PCR reactor enhanced the heating rate to 18.33 Cº/s and cooling rate to -3.11Cº/s because of the phonon scattering effect of TiO<sub>2</sub> in the reactor and successfully amplified λ-DNA (amplicon size of 100 bp) within 10 min. Finally, we improved the qPCR efficiency by 2 cycle threshold (C<sub>t</sub>) value compared with pristine PDMS reactor and quantified up to 10 copies/µL nucleic acids by fluorescence intensity enhancement resulting from light reflections property of TiO<sub>2</sub>. By using TiO<sub>2</sub>-PDMS nanocomposite-based PCR reactors, the fast and efficient nucleic acid assay was enabled without loss of sensitivity, and it can be practically used in the field of PoCT.

Journal of NanobiotechnologyVol. 23(1)
Sungkyunkwan University (KR)
Affordable and clean energy
Openalex Percentile: Top 5%
Biosensors and Analytical Detection
4.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.