High concentrations of aerosols can be generated within the sort collection area of cell sorters during instrument failures that cause the stream to deviate, such as a partial nozzle obstruction. Complete containment of these aerosol particles becomes essential for operator safety when working with potentially infectious or hazardous samples. Currently, aerosol containment is accomplished through the generation of continuous negative airflow within the sort collection area using an aerosol evacuation system, which can be enhanced by using primary containment devices such as biosafety cabinets. Unlike biosafety cabinets, many aerosol evacuation systems are not certified or tested on a regular basis after installation. Therefore, proper function of the system must be verified by the user prior to running hazardous samples to ensure that it is operational and provides sufficient protection for the operator. This protocol describes an updated procedure for verifying the containment and evacuation of aerosols generated when the stream is disrupted during an instrument failure. In this procedure, aerosols are generated to simulate a partial nozzle obstruction while running 1-µm fluorescent beads. Air samples are collected just outside the sort collection area using a disposable impactor-style aerosol sampler cassette and are examined for the presence of beads in an effort to detect aerosols. If no beads are present, aerosols were adequately contained and evacuated by the aerosol evacuation system. The presence of beads, however, indicates a potential failure of the aerosol evacuation system and/or other engineering controls that could result in the exposure of laboratory workers to any infectious or hazardous samples that are run through the instrument. © 2025 The Author(s). Current Protocols published by Wiley Periodicals LLC. This article has been contributed to by U.S. Government employees and their work is in the public domain in the USA. Basic Protocol: Validation of the aerosol evacuation system using 1-µm fluorescent beads and disposable aerosol sampler cassettes Support Protocol: Preparation of 1-µm fluorescent bead reference slide.

Authors

Institutions

Publication Details

Journal
Current Protocols
Published
2025-03-01
DOI
https://doi.org/10.1002/cpz1.70123
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verifying Proper Function of the Aerosol Evacuation System Prior to Sorting Potentially Infectious Samples

Suat Dervish, Alyssa C. Fears, Cecily C. Midkiff, Kristen M. Reifel et al.
Current Protocols
Infection Control and Ventilation
article

Verifying Proper Function of the Aerosol Evacuation System Prior to Sorting Potentially Infectious Samples

Suat Dervish, Alyssa C. Fears, Cecily C. Midkiff, Kristen M. Reifel, Iyadh Douagi, Matilda J. Moström, Stephen P. Perfetto, Evan R. Jellison, Avrill Aspland, Brandon K. Swan, James D. Thomas, Michael D. Solga, Taryn Mockus‐Daehn
article en

Abstract

High concentrations of aerosols can be generated within the sort collection area of cell sorters during instrument failures that cause the stream to deviate, such as a partial nozzle obstruction. Complete containment of these aerosol particles becomes essential for operator safety when working with potentially infectious or hazardous samples. Currently, aerosol containment is accomplished through the generation of continuous negative airflow within the sort collection area using an aerosol evacuation system, which can be enhanced by using primary containment devices such as biosafety cabinets. Unlike biosafety cabinets, many aerosol evacuation systems are not certified or tested on a regular basis after installation. Therefore, proper function of the system must be verified by the user prior to running hazardous samples to ensure that it is operational and provides sufficient protection for the operator. This protocol describes an updated procedure for verifying the containment and evacuation of aerosols generated when the stream is disrupted during an instrument failure. In this procedure, aerosols are generated to simulate a partial nozzle obstruction while running 1-µm fluorescent beads. Air samples are collected just outside the sort collection area using a disposable impactor-style aerosol sampler cassette and are examined for the presence of beads in an effort to detect aerosols. If no beads are present, aerosols were adequately contained and evacuated by the aerosol evacuation system. The presence of beads, however, indicates a potential failure of the aerosol evacuation system and/or other engineering controls that could result in the exposure of laboratory workers to any infectious or hazardous samples that are run through the instrument. © 2025 The Author(s). Current Protocols published by Wiley Periodicals LLC. This article has been contributed to by U.S. Government employees and their work is in the public domain in the USA. Basic Protocol: Validation of the aerosol evacuation system using 1-µm fluorescent beads and disposable aerosol sampler cassettes Support Protocol: Preparation of 1-µm fluorescent bead reference slide.

Current ProtocolsVol. 5(3)
Tulane University (US), The University of Sydney (AU), National Institutes of Health (US), Cleveland Clinic (US), University of Connecticut (US), Biomark (United States) (US), Vaccine & Gene Therapy Institute of Florida (US), National Institute of Allergy and Infectious Diseases (US), Westmead Institute for Medical Research (AU), University of Virginia (US), The University of Texas Medical Branch at Galveston (US)
University of Connecticut, Vaccine Research Center, National Institutes of Health, National Institute of Allergy and Infectious Diseases
Openalex Percentile: Top 92%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.