Kinetics Measurements in Resistive Electrolytes Using Ring-Disk Electrode: Ring as Current “Shield” Enables Uniform Disk Current Distribution

Rotating disk electrodes are commonly used for electrochemical kinetics measurements. A major disadvantage of these types of electrodes is their nonuniform secondary current distribution especially when performing electroanalytical measurements in resistive electrolytes. Such nonuniform current distribution can render the values of kinetics constants extracted from the disk electrode to be highly inaccurate. One emerging class of electrolytes that suffer from low ionic conductivities is deep eutectic solvents (DES). DES are a promising class of electrolytes for various emerging applications; however, due to their resistive nature, the secondary current distribution when using them is typically highly nonuniform. For example, the Wagner number when measuring Cu2+/Cu+ kinetics in choline chloride–ethylene glycol DES (1:4 molar ratio of ChCl:EG) is very low (<0.1), indicating highly nonuniform current distribution over the disk electrode. We show here that the Cu2+/Cu+ exchange current density measured using disk electrodes is very inaccurate due to the aforementioned nonuniform current distribution. To obtain uniform disk current distribution, we employ here a coplanar concentric rotating ring-disk electrode (RRDE), where the ring serves the function of a current “shield”. Specifically, we show using modeling that the ring minimizes the current distribution nonuniformity at the disk by effectively shielding the disk against current spikes near the disk edge. This enables improved precision in electrode kinetics measurements for the Cu2+/Cu+ couple in resistive DES. To enable broad applicability of this technique, an analytical expression based on the Wagner number is integrated into an iterative algorithm to help users identify ring conditions to achieve uniform current distribution and thus improved electroanalytics at the disk.

Authors

Institutions

Publication Details

Journal
ACS electrochemistry.
Published
2025-03-22
DOI
https://doi.org/10.1021/acselectrochem.4c00238
Primary Topic
Ionic liquids properties and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Kinetics Measurements in Resistive Electrolytes Using Ring-Disk Electrode: Ring as Current “Shield” Enables Uniform Disk Current Distribution

Rohan Akolkar, Nicholas Scott Sinclair, Vaishnavi Sree Jeganathan
ACS electrochemistry.
Ionic liquids properties and applications
article

Kinetics Measurements in Resistive Electrolytes Using Ring-Disk Electrode: Ring as Current “Shield” Enables Uniform Disk Current Distribution

Rohan Akolkar, Nicholas Scott Sinclair, Vaishnavi Sree Jeganathan
article en

Abstract

Rotating disk electrodes are commonly used for electrochemical kinetics measurements. A major disadvantage of these types of electrodes is their nonuniform secondary current distribution especially when performing electroanalytical measurements in resistive electrolytes. Such nonuniform current distribution can render the values of kinetics constants extracted from the disk electrode to be highly inaccurate. One emerging class of electrolytes that suffer from low ionic conductivities is deep eutectic solvents (DES). DES are a promising class of electrolytes for various emerging applications; however, due to their resistive nature, the secondary current distribution when using them is typically highly nonuniform. For example, the Wagner number when measuring Cu2+/Cu+ kinetics in choline chloride–ethylene glycol DES (1:4 molar ratio of ChCl:EG) is very low (<0.1), indicating highly nonuniform current distribution over the disk electrode. We show here that the Cu2+/Cu+ exchange current density measured using disk electrodes is very inaccurate due to the aforementioned nonuniform current distribution. To obtain uniform disk current distribution, we employ here a coplanar concentric rotating ring-disk electrode (RRDE), where the ring serves the function of a current “shield”. Specifically, we show using modeling that the ring minimizes the current distribution nonuniformity at the disk by effectively shielding the disk against current spikes near the disk edge. This enables improved precision in electrode kinetics measurements for the Cu2+/Cu+ couple in resistive DES. To enable broad applicability of this technique, an analytical expression based on the Wagner number is integrated into an iterative algorithm to help users identify ring conditions to achieve uniform current distribution and thus improved electroanalytics at the disk.

ACS electrochemistry.Vol. 1(7)
Case Western Reserve University (US)
Basic Energy Sciences
Affordable and clean energy
Openalex Percentile: Top 98%
Ionic liquids properties and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.