Grid Synchronization during Non-Ideal Grid Conditions Based on Double Integration Method

Modular multilevel converter (MMC) has numerous advantages already discussed in the literature. Grid voltage synchronization is a critical component of grid-connected power converters. Synchronous reference frame (SRF)-PLL traditionally synchronizes MMC voltage to the grid. However, non-ideal grid circumstances induce phase angle inaccuracies since phase angle is obtained by integrating grid frequency. The three-phase dual integration method (DIM) is used in the grid synchronization of a three-phase MMC inverter in this study. It integrates grid phase voltage twice to generate reference signals for the MMC grid side converter. Furthermore, it enables a smooth start during balanced and non-ideal grid conditions a) voltage unbalance; and b) frequency unbalance, as the generated signal remains in phase with the current. The proposed process reduces THD to almost less than (< 0.09%). The simulation results demonstrate the suggested method's efficacy in grid synchronization.

Institutions

Publication Details

Journal
International Journal of Renewable Energy Research
Published
2025-01-01
DOI
https://doi.org/10.20508/ijrer.v15i1.14733.g9029
Citations
1
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid Synchronization during Non-Ideal Grid Conditions Based on Double Integration Method

1 citations
International Journal of Renewable Energy Research
Power Systems and Renewable Energy
0.53
article

Grid Synchronization during Non-Ideal Grid Conditions Based on Double Integration Method

article en
1 citations

Abstract

Modular multilevel converter (MMC) has numerous advantages already discussed in the literature. Grid voltage synchronization is a critical component of grid-connected power converters. Synchronous reference frame (SRF)-PLL traditionally synchronizes MMC voltage to the grid. However, non-ideal grid circumstances induce phase angle inaccuracies since phase angle is obtained by integrating grid frequency. The three-phase dual integration method (DIM) is used in the grid synchronization of a three-phase MMC inverter in this study. It integrates grid phase voltage twice to generate reference signals for the MMC grid side converter. Furthermore, it enables a smooth start during balanced and non-ideal grid conditions a) voltage unbalance; and b) frequency unbalance, as the generated signal remains in phase with the current. The proposed process reduces THD to almost less than (< 0.09%). The simulation results demonstrate the suggested method's efficacy in grid synchronization.

International Journal of Renewable Energy Research(V15i1)
COMSATS University Islamabad (PK), Ghent University (BE), Middle Technical University (IQ)
Openalex Percentile: Top 33%
Power Systems and Renewable Energy
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Grid Synchronization during Non-Ideal Grid Conditions Based on Double Integration Method · International Journal of Renewable Energy Research (2025) | TGRS Research Map | TGRS