Med-VQA: Performance Analysis of Question-Answering Systems on Medical Images

This study explores multimodal fusion methods and deep learning architectures for visual question answering (VQA) systems in the healthcare domain. ResNet50, DenseNet, LSTM, and BiLSTM models were evaluated for image feature extraction and text-based question processing, along with their integration into architectures enhanced by attention mechanisms. The ResNet50+DenseNet+LSTM model achieved the highest accuracy of 74.90% on the VQA-RAD dataset. Models such as ResNet50+DenseNet+BiLSTM and ResNet50+DenseNet+BiLSTM+Attention demonstrated strong performance with an accuracy of 72.80%, whereas the ResNet50+DenseNet+LSTM+Attention model showed comparatively lower performance. The results highlight the effectiveness of deep learning-based models, particularly in contextual information extraction and multimodal data fusion. This study underscores the significance of leveraging deep learning architectures in VQA systems to generate accurate and context-aware responses, especially in critical domains like healthcare.

Authors

Institutions

Publication Details

Published
2025-02-19
DOI
https://doi.org/10.1109/it64745.2025.10930288
Citations
1
Primary Topic
Image Retrieval and Classification Techniques
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Med-VQA: Performance Analysis of Question-Answering Systems on Medical Images

Zeki Karaca, İlhan Aydın
1 citations
Image Retrieval and Classification Techniques
1.28
article

Med-VQA: Performance Analysis of Question-Answering Systems on Medical Images

Zeki Karaca, İlhan Aydın
article en
1 citations

Abstract

This study explores multimodal fusion methods and deep learning architectures for visual question answering (VQA) systems in the healthcare domain. ResNet50, DenseNet, LSTM, and BiLSTM models were evaluated for image feature extraction and text-based question processing, along with their integration into architectures enhanced by attention mechanisms. The ResNet50+DenseNet+LSTM model achieved the highest accuracy of 74.90% on the VQA-RAD dataset. Models such as ResNet50+DenseNet+BiLSTM and ResNet50+DenseNet+BiLSTM+Attention demonstrated strong performance with an accuracy of 72.80%, whereas the ResNet50+DenseNet+LSTM+Attention model showed comparatively lower performance. The results highlight the effectiveness of deep learning-based models, particularly in contextual information extraction and multimodal data fusion. This study underscores the significance of leveraging deep learning architectures in VQA systems to generate accurate and context-aware responses, especially in critical domains like healthcare.

Fırat University (TR)
Gender equality
Openalex Percentile: Top 22%
Image Retrieval and Classification Techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.