Case report: False-positive B-type natriuretic peptide results with the cyclic amplified fluorescence immunoassay

B-type natriuretic peptide, which was initially isolated from porcine brain tissue, has been used in the clinic as an important indicator for the diagnosis, risk stratification, and prognosis of heart failure. In recent years, many commercial immunoassays to assess B-type natriuretic peptide have been reported to undergo interference due to various factors. At present, the commonly used assays to assess B-type natriuretic peptide are enzyme-linked immunosorbent assay and direct chemiluminescence, which are based on a "sandwich structure" formed by dual antibodies; both assays have been reported to undergo interference. We report the case of a patient whose B-type natriuretic peptide results, which were detected using a cyclic amplified fluorescence immunoassay, were false-positive. The patient had a low-risk pulmonary embolism without right heart failure; however, her B-type natriuretic peptide results were surprisingly high. Further study confirmed that the abnormal B-type natriuretic peptide result was caused by the interference of the human anti-mouse antibodies. Therefore, when encountering B-type natriuretic peptide results that are not consistent with the clinical situation, the possibility of interference in the assay should be considered.

Authors

Institutions

Publication Details

Journal
Journal of International Medical Research
Published
2025-03-01
DOI
https://doi.org/10.1177/03000605251325942
Primary Topic
Heart Failure Treatment and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case report: False-positive B-type natriuretic peptide results with the cyclic amplified fluorescence immunoassay

Yi-bin Pan, Chen Zhang, Fei Wang, Qian Yin
Journal of International Medical Research
Heart Failure Treatment and Management
article

Case report: False-positive B-type natriuretic peptide results with the cyclic amplified fluorescence immunoassay

Yi-bin Pan, Chen Zhang, Fei Wang, Qian Yin
article en

Abstract

B-type natriuretic peptide, which was initially isolated from porcine brain tissue, has been used in the clinic as an important indicator for the diagnosis, risk stratification, and prognosis of heart failure. In recent years, many commercial immunoassays to assess B-type natriuretic peptide have been reported to undergo interference due to various factors. At present, the commonly used assays to assess B-type natriuretic peptide are enzyme-linked immunosorbent assay and direct chemiluminescence, which are based on a "sandwich structure" formed by dual antibodies; both assays have been reported to undergo interference. We report the case of a patient whose B-type natriuretic peptide results, which were detected using a cyclic amplified fluorescence immunoassay, were false-positive. The patient had a low-risk pulmonary embolism without right heart failure; however, her B-type natriuretic peptide results were surprisingly high. Further study confirmed that the abnormal B-type natriuretic peptide result was caused by the interference of the human anti-mouse antibodies. Therefore, when encountering B-type natriuretic peptide results that are not consistent with the clinical situation, the possibility of interference in the assay should be considered.

Journal of International Medical ResearchVol. 53(3)
Zhejiang University (CN)
Good health and well-being
Openalex Percentile: Top 92%
Heart Failure Treatment and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Case report: False-positive B-type natriuretic peptide results with the cyclic amplified fluorescence immunoassay — Yi-bin Pan, Chen Zhang, et al. · Journal of International Medical Research (2025) | TGRS Research Map | TGRS