Optimizing thermal performance of hollow cylindrical latent heat storage units: Insights into geometry-driven heat transfer enhancements

The thermal performance of cylindrical latent heat storage units (C-LHSUs) in hot water tanks can be improved by using a hollow geometry structure, which effectively reduces the average distance between the heated/cooled wall and the solid-liquid interface during the charging and discharging process. To comprehensively evaluate this improvement, an unconstrained melting model for phase change materials (PCMs) was developed, enabling detailed investigation of the thermal behavior of hollow geometry LHSUs (H-LHSUs). Moreover, the impact of the ratio between the inner hollow tube radius ( r ) and outer tube radius ( R ) on the charging/discharging performance of H-LHSUs was analyzed. The results demonstrated substantial enhancements in heat transfer performance for H-LHSUs compared to conventional C-LHSUs. Specifically, the average heat transfer coefficient increased by 82.9 % during charging and 176.47 % during discharging. This improvement translated to a charging rate that was 2.46 times and a discharging rate that was 3.9 times higher than those of the C-LHSU. Furthermore, the study revealed that as the r/R ratio increased, both charging and discharging rates improved significantly, with the rate of heat transfer enhancement becoming more pronounced at higher r/R values. This research provides actionable insights for optimizing the design of LHSUs in practical applications. It underscores the importance of balancing thermal performance gains with the associated capital costs when selecting the optimal r/R ratio. The findings contribute to the advancement of energy storage technologies, offering a robust framework for improving the efficiency of thermal energy systems in hot water tanks. • H-LHSU significantly enhanced the conduction and convection. • The charging and discharging rate were significantly improved. • The charging and discharging rate increase with the increase of r/R. • Enhancement in heat transfer of H-LHSUs becomes more significant as r/R rises.

Authors

Institutions

Publication Details

Journal
Energy
Published
2025-03-22
DOI
https://doi.org/10.1016/j.energy.2025.135750
Citations
1
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing thermal performance of hollow cylindrical latent heat storage units: Insights into geometry-driven heat transfer enhancements

Ke Liang, Zhengxuan Liu, Yongqiang Luo, Yan Zhong-jun et al.
1 citations
Energy
Phase Change Materials Research
0.71
article

Optimizing thermal performance of hollow cylindrical latent heat storage units: Insights into geometry-driven heat transfer enhancements

Ke Liang, Zhengxuan Liu, Yongqiang Luo, Yan Zhong-jun, Wang Chen, Yuan Zhang, Shulin Pan
article en
1 citations

Abstract

The thermal performance of cylindrical latent heat storage units (C-LHSUs) in hot water tanks can be improved by using a hollow geometry structure, which effectively reduces the average distance between the heated/cooled wall and the solid-liquid interface during the charging and discharging process. To comprehensively evaluate this improvement, an unconstrained melting model for phase change materials (PCMs) was developed, enabling detailed investigation of the thermal behavior of hollow geometry LHSUs (H-LHSUs). Moreover, the impact of the ratio between the inner hollow tube radius ( r ) and outer tube radius ( R ) on the charging/discharging performance of H-LHSUs was analyzed. The results demonstrated substantial enhancements in heat transfer performance for H-LHSUs compared to conventional C-LHSUs. Specifically, the average heat transfer coefficient increased by 82.9 % during charging and 176.47 % during discharging. This improvement translated to a charging rate that was 2.46 times and a discharging rate that was 3.9 times higher than those of the C-LHSU. Furthermore, the study revealed that as the r/R ratio increased, both charging and discharging rates improved significantly, with the rate of heat transfer enhancement becoming more pronounced at higher r/R values. This research provides actionable insights for optimizing the design of LHSUs in practical applications. It underscores the importance of balancing thermal performance gains with the associated capital costs when selecting the optimal r/R ratio. The findings contribute to the advancement of energy storage technologies, offering a robust framework for improving the efficiency of thermal energy systems in hot water tanks. • H-LHSU significantly enhanced the conduction and convection. • The charging and discharging rate were significantly improved. • The charging and discharging rate increase with the increase of r/R. • Enhancement in heat transfer of H-LHSUs becomes more significant as r/R rises.

EnergyVol. 322
Hunan University of Humanities, Science and Technology (CN), Huazhong University of Science and Technology (CN), Delft University of Technology (NL)
Affordable and clean energy
Openalex Percentile: Top 35%
Phase Change Materials Research
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.