A groupwise multiresolution network for DCE-MRI image registration

In four-dimensional time series such as dynamic contrast-enhanced (DCE) MRI, motion between individual time steps due to the patient's breathing or movement leads to incorrect image analysis, e.g., when calculating perfusion. Image registration of the volumes of the individual time steps is necessary to improve the accuracy of the subsequent image analysis. Both groupwise and multiresolution registration methods have shown great potential for medical image registration. To combine the advantages of groupwise and multiresolution registration, we proposed a groupwise multiresolution network for deformable medical image registration. We applied our proposed method to the registration of DCE-MR images for the assessment of lung perfusion in patients with congenital diaphragmatic hernia. The networks were trained unsupervised with Mutual Information and Gradient L2 loss. We compared the groupwise networks with a pairwise deformable registration network and a published groupwise network as benchmarks and the classical registration method SimpleElastix as baseline using four-dimensional DCE-MR scans of patients after congenital diaphragmatic hernia repair. Experimental results showed that our groupwise network yields results with high spatial alignment (SSIM up to 0.953 ± 0.025 or 0.936 ± 0.028 respectively), medically plausible transformation with low image folding (|J| ≤ 0: 0.0 ± 0.0%), and a low registration time of less than 10 seconds for a four-dimensional DCE-MR scan with 50 time steps. Furthermore, our results demonstrate that image registration with the proposed groupwise network enhances the accuracy of medical image analysis by leading to more homogeneous perfusion maps.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-22
DOI
https://doi.org/10.1038/s41598-025-94275-9
Citations
1
Primary Topic
Congenital Diaphragmatic Hernia Studies
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A groupwise multiresolution network for DCE-MRI image registration

Anika Strittmatter, Meike Weis, Frank G. Zöllner
1 citations
Scientific Reports
Congenital Diaphragmatic Hernia Studies
2.01
article

A groupwise multiresolution network for DCE-MRI image registration

Anika Strittmatter, Meike Weis, Frank G. Zöllner
article en
1 citations

Abstract

In four-dimensional time series such as dynamic contrast-enhanced (DCE) MRI, motion between individual time steps due to the patient's breathing or movement leads to incorrect image analysis, e.g., when calculating perfusion. Image registration of the volumes of the individual time steps is necessary to improve the accuracy of the subsequent image analysis. Both groupwise and multiresolution registration methods have shown great potential for medical image registration. To combine the advantages of groupwise and multiresolution registration, we proposed a groupwise multiresolution network for deformable medical image registration. We applied our proposed method to the registration of DCE-MR images for the assessment of lung perfusion in patients with congenital diaphragmatic hernia. The networks were trained unsupervised with Mutual Information and Gradient L2 loss. We compared the groupwise networks with a pairwise deformable registration network and a published groupwise network as benchmarks and the classical registration method SimpleElastix as baseline using four-dimensional DCE-MR scans of patients after congenital diaphragmatic hernia repair. Experimental results showed that our groupwise network yields results with high spatial alignment (SSIM up to 0.953 ± 0.025 or 0.936 ± 0.028 respectively), medically plausible transformation with low image folding (|J| ≤ 0: 0.0 ± 0.0%), and a low registration time of less than 10 seconds for a four-dimensional DCE-MR scan with 50 time steps. Furthermore, our results demonstrate that image registration with the proposed groupwise network enhances the accuracy of medical image analysis by leading to more homogeneous perfusion maps.

Scientific ReportsVol. 15(1)
Heidelberg University (DE), University Hospital Heidelberg (DE), University Medical Centre Mannheim (DE)
Openalex Percentile: Top 18%
Congenital Diaphragmatic Hernia Studies
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.