Real-time assessment of graft oxygenation and perfusion using spectral imaging for improved outcome in esophageal cancer surgery

Esophageal cancer surgery is challenged by anastomotic leakage (AL), affecting 8-20% of patients and leading to a prolonged hospital stay, severe morbidity or even death. Tissue hypoxia at the surgical connection site is a primary cause of AL, highlighting the critical need for reliable intraoperative hypoxia monitoring. This study presents initial findings from a clinical evaluation of real-time multispectral imaging (MSI) as a non-invasive tool for use during laparoscopic esophagectomy in humans. MSI of the stomach graft was conducted at video rate using a snapshot camera operating in the 460 - 600 nm spectral range. Tissue oxygenation was visualized and compared to indocyanine green fluorescence imaging (ICG-FI) and capillary lactate measurements. Preliminary results revealed critically low oxygenation levels (8.10 ± 5.99%) at the anastomotic site in a patient with AL, compared to higher levels (60.65 ± 12.83%) in a patient without AL. Furthermore, MSI and ICG-FI are found complementary, but discrepancies arise when assessing the ideal anastomotic site. These findings highlight MSI’s potential as a non-invasive and real-time intraoperative method of tissue hypoxia assessment, possibly reducing AL rates and improving surgical outcomes.

Authors

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3042274
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time assessment of graft oxygenation and perfusion using spectral imaging for improved outcome in esophageal cancer surgery

Siri Luthman, Wim Ceelen, Danilo Babin, Hiêp Luong et al.
Radiomics and Machine Learning in Medical Imaging
article

Real-time assessment of graft oxygenation and perfusion using spectral imaging for improved outcome in esophageal cancer surgery

Siri Luthman, Wim Ceelen, Danilo Babin, Hiêp Luong, Hanne Vanommeslaeghe, Elke Van Daele, Jens De Winne
article en

Abstract

Esophageal cancer surgery is challenged by anastomotic leakage (AL), affecting 8-20% of patients and leading to a prolonged hospital stay, severe morbidity or even death. Tissue hypoxia at the surgical connection site is a primary cause of AL, highlighting the critical need for reliable intraoperative hypoxia monitoring. This study presents initial findings from a clinical evaluation of real-time multispectral imaging (MSI) as a non-invasive tool for use during laparoscopic esophagectomy in humans. MSI of the stomach graft was conducted at video rate using a snapshot camera operating in the 460 - 600 nm spectral range. Tissue oxygenation was visualized and compared to indocyanine green fluorescence imaging (ICG-FI) and capillary lactate measurements. Preliminary results revealed critically low oxygenation levels (8.10 ± 5.99%) at the anastomotic site in a patient with AL, compared to higher levels (60.65 ± 12.83%) in a patient without AL. Furthermore, MSI and ICG-FI are found complementary, but discrepancies arise when assessing the ideal anastomotic site. These findings highlight MSI’s potential as a non-invasive and real-time intraoperative method of tissue hypoxia assessment, possibly reducing AL rates and improving surgical outcomes.

Good health and well-being
Openalex Percentile: Top 92%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.