Steady state versus time-resolved photoplethysmography (PPG): the effect of epidermal thickness (Conference Presentation)

The photoplethysmography (PPG) sensors commonly used in wearable devices rely on changes in the diffuse reflection of light on the skin to detect heart rate. These changes are primarily due to the varying volume of blood in the tissue throughout the cardiac cycle. In this study, we consider three different epidermal thicknesses and study their effects on PPG signal. This is accomplished by using Monte Carlo eXtreme (MCX) to evaluate the photon path length in the tissue. We will study the phenomenon using both continuous wave (steady state) PPG which is a standard format in common wearables, and time-of-flight (time-resolved) PPG. Experimental validation on hemoglobin phantoms will be performed at common wavelengths (between 500 and 900 nm) for steady state cases whereas TOF-PPG will be studied using a system consisting of a pulse laser with wavelength at 780 nm, single-photon avalanche diodes, and a multi-channel time-correlated single photon counter.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3050156
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Steady state versus time-resolved photoplethysmography (PPG): the effect of epidermal thickness (Conference Presentation)

Vinh Nguyen Du Le, Elizabeth Badolato, Sophia Fronckowiak
Non-Invasive Vital Sign Monitoring
article

Steady state versus time-resolved photoplethysmography (PPG): the effect of epidermal thickness (Conference Presentation)

Vinh Nguyen Du Le, Elizabeth Badolato, Sophia Fronckowiak
article en

Abstract

The photoplethysmography (PPG) sensors commonly used in wearable devices rely on changes in the diffuse reflection of light on the skin to detect heart rate. These changes are primarily due to the varying volume of blood in the tissue throughout the cardiac cycle. In this study, we consider three different epidermal thicknesses and study their effects on PPG signal. This is accomplished by using Monte Carlo eXtreme (MCX) to evaluate the photon path length in the tissue. We will study the phenomenon using both continuous wave (steady state) PPG which is a standard format in common wearables, and time-of-flight (time-resolved) PPG. Experimental validation on hemoglobin phantoms will be performed at common wavelengths (between 500 and 900 nm) for steady state cases whereas TOF-PPG will be studied using a system consisting of a pulse laser with wavelength at 780 nm, single-photon avalanche diodes, and a multi-channel time-correlated single photon counter.

University of Alabama in Huntsville (US)
Openalex Percentile: Top 95%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.