Optimizing Raman modalities in PDMS-based microfluidic devices for cancer detection and prognostic applications (Conference Presentation)

3D culture on microfluidic devices holds great potential for in vivo behavior representation, but faces inherent challenges, particularly in distinguishing cancerous from healthy tissue. We propose here to use Raman spectroscopy on microfluidic chips to achieve on-chip tissue differentiation. This study optimizes Raman spectrum acquisition for better signal-to-noise ratio and acquisition speed, examining PDMS parasitic spectrum, thickness, probe distance, sample size, signal specificity, and intensity. Results show an optimal Raman shift window for PDMS acquisitions, with ideal PDMS thickness under 4mm, sample distance of at least 0.50mm, and sample thickness no more than 1mm. These configurations enhance signal detection accuracy.

Authors

Institutions

Publication Details

Published
2025-03-20
DOI
https://doi.org/10.1117/12.3043982
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Raman modalities in PDMS-based microfluidic devices for cancer detection and prognostic applications (Conference Presentation)

Thomas Gervais, Frédéric Leblond, Tommy Brasseur
Spectroscopy Techniques in Biomedical and Chemical Research
article

Optimizing Raman modalities in PDMS-based microfluidic devices for cancer detection and prognostic applications (Conference Presentation)

Thomas Gervais, Frédéric Leblond, Tommy Brasseur
article en

Abstract

3D culture on microfluidic devices holds great potential for in vivo behavior representation, but faces inherent challenges, particularly in distinguishing cancerous from healthy tissue. We propose here to use Raman spectroscopy on microfluidic chips to achieve on-chip tissue differentiation. This study optimizes Raman spectrum acquisition for better signal-to-noise ratio and acquisition speed, examining PDMS parasitic spectrum, thickness, probe distance, sample size, signal specificity, and intensity. Results show an optimal Raman shift window for PDMS acquisitions, with ideal PDMS thickness under 4mm, sample distance of at least 0.50mm, and sample thickness no more than 1mm. These configurations enhance signal detection accuracy.

Polytechnique Montréal (CA)
Good health and well-being
Openalex Percentile: Top 95%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.