Microfiber suspensions for the removal of adhered colloids from surfaces, microdevices, and cavities

Effective methods for cleaning surfaces are important for applications including dentistry, healthcare, micro-devices, and the manufacturing of electronic components and semiconductors. For example, surgical and dental instruments are susceptible to accumulation of aggregates and biofilm formation, which can lead to cross-contamination when ineffectively cleaned and reused. Complex fluids such as micro-fibrillated cellulose (MFC) can greatly assist in mechanically cleaning surfaces by removing strongly adhered aggregates without abrading the underlying material. We demonstrate that the heterogeneous structure of micro-fibrillated cellulose is effective in removing adhered particulates from surfaces and we characterize the cleaning efficiency of MFC suspensions in representative flow configurations. The experiments reported here involve flowing MFC solutions at various concentrations and at controlled shear rates through a rectangular microfluidic channel. Fluorescence microscopy is used to measure the removal of fluorescent particles that are adhered to the glass surface of the microfluidic device by electrostatic and surface forces. The particle removal with time is analyzed for each concentration of the MFC suspension and each shear rate to determine cleaning effectiveness. The rheology of the MFC solutions is also characterized and correlated to cleaning performance. We find that cleaning effectiveness increases with increasing fiber concentration and with increasing shear rate. Additionally, we compared the cleaning performance of the MFC suspensions with fluids that share similar rheological properties to highlight the role of shear thinning, elasticity, and tribology. Finally, we examine how sharp corners/edges within a microfluidic channel hinder cleaning and identify strategies for mitigating this hindrance.

Authors

Institutions

Publication Details

Journal
Soft Matter
Published
2025-01-01
DOI
https://doi.org/10.1039/d5sm00065c
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfiber suspensions for the removal of adhered colloids from surfaces, microdevices, and cavities

Samantha A. McBride, Marcel Louis, Janine K. Nunes, Mohamed E. Labib et al.
Soft Matter
Innovative Microfluidic and Catalytic Techniques Innovation
article

Microfiber suspensions for the removal of adhered colloids from surfaces, microdevices, and cavities

Samantha A. McBride, Marcel Louis, Janine K. Nunes, Mohamed E. Labib, Antonio Perazzo, Howard A. Stone, Christopher A Kuchar
article en

Abstract

Effective methods for cleaning surfaces are important for applications including dentistry, healthcare, micro-devices, and the manufacturing of electronic components and semiconductors. For example, surgical and dental instruments are susceptible to accumulation of aggregates and biofilm formation, which can lead to cross-contamination when ineffectively cleaned and reused. Complex fluids such as micro-fibrillated cellulose (MFC) can greatly assist in mechanically cleaning surfaces by removing strongly adhered aggregates without abrading the underlying material. We demonstrate that the heterogeneous structure of micro-fibrillated cellulose is effective in removing adhered particulates from surfaces and we characterize the cleaning efficiency of MFC suspensions in representative flow configurations. The experiments reported here involve flowing MFC solutions at various concentrations and at controlled shear rates through a rectangular microfluidic channel. Fluorescence microscopy is used to measure the removal of fluorescent particles that are adhered to the glass surface of the microfluidic device by electrostatic and surface forces. The particle removal with time is analyzed for each concentration of the MFC suspension and each shear rate to determine cleaning effectiveness. The rheology of the MFC solutions is also characterized and correlated to cleaning performance. We find that cleaning effectiveness increases with increasing fiber concentration and with increasing shear rate. Additionally, we compared the cleaning performance of the MFC suspensions with fluids that share similar rheological properties to highlight the role of shear thinning, elasticity, and tribology. Finally, we examine how sharp corners/edges within a microfluidic channel hinder cleaning and identify strategies for mitigating this hindrance.

Soft MatterVol. 21(17)
Princeton University (US), NovaFlux (United States) (US), University of Pennsylvania (US)
Princeton University, Materials Research Science and Engineering Center, Harvard University, Division of Materials Research
Openalex Percentile: Top 95%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.