Aberration Correction for Retinal Imaging by Magnetic Fluid Deformable Mirror With Dual-Layer Actuators

Adaptive optics (AOs) is widely used to correct aberrations in human eye to obtain high-resolution retinal images. The existing single wavefront corrector is difficult to correct both low-order and high-order human eye aberrations for all possible cases. To improve the universality of the AO imaging system, in this article a magnetic fluid deformable mirror (MFDM) with dual-layer actuators is designed and implemented in the retinal imaging system for large aberration correction. The structure of the dual-layer MFDM is first designed, then a hybrid algorithm is proposed to control the designed MFDM. Experimental evaluation of the effectiveness of the designed dual-layer MFDM and the hybrid control algorithm is conducted in the retinal imaging system. The results show that the system can simultaneously correct both low-order and high-order aberrations during imaging and obtain high-quality images.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3553190
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aberration Correction for Retinal Imaging by Magnetic Fluid Deformable Mirror With Dual-Layer Actuators

Zhizheng Wu, T.T. Liu, Haichun Ding, Tao Wang et al.
IEEE Transactions on Instrumentation and Measurement
Retinal and Macular Surgery
article

Aberration Correction for Retinal Imaging by Magnetic Fluid Deformable Mirror With Dual-Layer Actuators

Zhizheng Wu, T.T. Liu, Haichun Ding, Tao Wang, Jiyuan Zhao
article en

Abstract

Adaptive optics (AOs) is widely used to correct aberrations in human eye to obtain high-resolution retinal images. The existing single wavefront corrector is difficult to correct both low-order and high-order human eye aberrations for all possible cases. To improve the universality of the AO imaging system, in this article a magnetic fluid deformable mirror (MFDM) with dual-layer actuators is designed and implemented in the retinal imaging system for large aberration correction. The structure of the dual-layer MFDM is first designed, then a hybrid algorithm is proposed to control the designed MFDM. Experimental evaluation of the effectiveness of the designed dual-layer MFDM and the hybrid control algorithm is conducted in the retinal imaging system. The results show that the system can simultaneously correct both low-order and high-order aberrations during imaging and obtain high-quality images.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Shanghai University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 92%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aberration Correction for Retinal Imaging by Magnetic Fluid Deformable Mirror With Dual-Layer Actuators — Zhizheng Wu, T.T. Liu, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS