A Novel Magnetic Thermal Stability Index System for Evaluating the Temperature Effects on Magnetic Fields in High-Homogeneity Portable Whole-Body MRI

The stability of magnetic fields under variable temperatures is essential for the effectiveness of portable magnetic resonance imaging (MRI) systems. This research proposes the magnetic thermal stability (MTS) index system, a novel metric to comprehensively evaluate the effects of average temperatures and the temperature range on the average magnetic field strength and magnetic field homogeneity. Employing the improved gray wolf optimization (IGWO) algorithm alongside an analytical model of the Halbach magnet array, a comprehensive whole-body magnet structure model was designed to precisely assess the effects of temperature fluctuations on magnetic field stability. The optimized design achieved an ultra-light whole-body MRI magnet structure with high magnetic field homogeneity of 188 ppm (parts per million) and a total weight of 201 kg. Additionally, extensive analysis of neodymium-ferrite-boron (NdFeB) and samarium-cobalt (SmCo) magnets under varying temperature conditions demonstrated that the temperature range significantly influences magnetic field stability. The drift coefficients of the average magnetic field for NdFeB and SmCo magnets are −1260 and −400 ppm/°C, respectively. Specifically, NdFeB magnets exhibit a homogeneity drift coefficient of 135 ppm/°C, while SmCo magnets demonstrate superior stability with a homogeneity drift coefficient of 40 ppm/°C. Notably, the observed drift coefficient exceeds its inherent temperature coefficient due to additional factors proposed by temperature fluctuations. The MTS index system proves to be a valuable tool for optimizing magnet, critical for deploying MRI in environments with fluctuating temperatures.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3553265
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Magnetic Thermal Stability Index System for Evaluating the Temperature Effects on Magnetic Fields in High-Homogeneity Portable Whole-Body MRI

Xia Xiao, Zhenchang Wang, Yanwei Pang, Jiannan Zhou
1 citations
IEEE Transactions on Instrumentation and Measurement
Advanced MRI Techniques and Applications
1.36
article

A Novel Magnetic Thermal Stability Index System for Evaluating the Temperature Effects on Magnetic Fields in High-Homogeneity Portable Whole-Body MRI

Xia Xiao, Zhenchang Wang, Yanwei Pang, Jiannan Zhou
article en
1 citations

Abstract

The stability of magnetic fields under variable temperatures is essential for the effectiveness of portable magnetic resonance imaging (MRI) systems. This research proposes the magnetic thermal stability (MTS) index system, a novel metric to comprehensively evaluate the effects of average temperatures and the temperature range on the average magnetic field strength and magnetic field homogeneity. Employing the improved gray wolf optimization (IGWO) algorithm alongside an analytical model of the Halbach magnet array, a comprehensive whole-body magnet structure model was designed to precisely assess the effects of temperature fluctuations on magnetic field stability. The optimized design achieved an ultra-light whole-body MRI magnet structure with high magnetic field homogeneity of 188 ppm (parts per million) and a total weight of 201 kg. Additionally, extensive analysis of neodymium-ferrite-boron (NdFeB) and samarium-cobalt (SmCo) magnets under varying temperature conditions demonstrated that the temperature range significantly influences magnetic field stability. The drift coefficients of the average magnetic field for NdFeB and SmCo magnets are −1260 and −400 ppm/°C, respectively. Specifically, NdFeB magnets exhibit a homogeneity drift coefficient of 135 ppm/°C, while SmCo magnets demonstrate superior stability with a homogeneity drift coefficient of 40 ppm/°C. Notably, the observed drift coefficient exceeds its inherent temperature coefficient due to additional factors proposed by temperature fluctuations. The MTS index system proves to be a valuable tool for optimizing magnet, critical for deploying MRI in environments with fluctuating temperatures.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Tianjin University of Technology (CN), Tianjin University (CN), Capital Medical University (CN), Beijing Friendship Hospital (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 22%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.