Quantitative mapping of cerebrovascular reactivity amplitude and delay with breath-hold BOLD fMRI when end-tidal CO2 quality is low

Cerebrovascular reactivity (CVR), the ability of cerebral blood vessels to dilate or constrict in response to a vasoactive stimulus, is a clinically useful measure of cerebrovascular health. CVR is often measured using a breath-hold task to modulate blood CO<sub>2</sub>levels during an fMRI scan. Measuring end-tidal CO<sub>2</sub>(P<sub>ET</sub>CO<sub>2</sub>) with a nasal cannula during the task allows CVR amplitude to be calculated in standard units (vascular response per unit change in CO<sub>2</sub>, or %BOLD/mmHg) and CVR delay to be calculated in seconds. The use of standard units allows for normative CVR ranges to be established and for CVR comparisons to be made across subjects and scan sessions. Although breath holding can be successfully performed by diverse patient populations, obtaining accurate P<sub>ET</sub>CO<sub>2</sub>measurements requires additional task compliance; specifically, participants must breathe exclusively through their nose and exhale immediately before and after each breath hold. Meeting these requirements is challenging, even in healthy participants, and this has limited the translational potential of breath-hold fMRI for CVR mapping. Previous work has focused on using alternative regressors such as respiration volume per time (RVT), derived from respiration-belt measurements, to map CVR. Because measuring RVT does not require additional task compliance from participants, it is a more feasible measure than P<sub>ET</sub>CO<sub>2</sub>. However, using RVT does not produce CVR amplitude in standard units. In this work, we explored how to achieve CVR amplitude maps, in standard units, and CVR delay maps, when breath-hold task P<sub>ET</sub>CO<sub>2</sub>data quality is low. First, we evaluated whether RVT could be scaled to units of mmHg using a subset of P<sub>ET</sub>CO<sub>2</sub>data of sufficiently high quality. Second, we explored whether a P<sub>ET</sub>CO<sub>2</sub>timeseries predicted from RVT using deep learning allows for more accurate CVR measurements. Using a dense-mapping breath-hold fMRI dataset, we showed that both rescaled RVT and rescaled, predicted P<sub>ET</sub>CO<sub>2</sub>can be used to produce maps of CVR amplitude in standard units and CVR delay with strong absolute agreement to ground-truth maps. The rescaled, predicted P<sub>ET</sub>CO<sub>2</sub>regressor resulted in superior accuracy for both CVR amplitude and delay. In an individual with regions of increased CVR delay due to Moyamoya disease, the predicted P<sub>ET</sub>CO<sub>2</sub>regressor also provided greater sensitivity to pathology than RVT. Ultimately, this work will increase the clinical applicability of CVR in populations exhibiting decreased task compliance.

Authors

Institutions

Publication Details

Journal
Imaging Neuroscience
Published
2025-01-01
DOI
https://doi.org/10.1162/imag_a_00536
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative mapping of cerebrovascular reactivity amplitude and delay with breath-hold BOLD fMRI when end-tidal CO2 quality is low

Molly G. Bright, Neha Reddy, Kimberly J. Hemmerling, Roza G. Bayrak et al.
1 citations
Imaging Neuroscience
Optical Imaging and Spectroscopy Techniques
1.36
article

Quantitative mapping of cerebrovascular reactivity amplitude and delay with breath-hold BOLD fMRI when end-tidal CO2 quality is low

Molly G. Bright, Neha Reddy, Kimberly J. Hemmerling, Roza G. Bayrak, Catie Chang, Rebecca G. Clements, Kristina M. Zvolanek
article en
1 citations

Abstract

Cerebrovascular reactivity (CVR), the ability of cerebral blood vessels to dilate or constrict in response to a vasoactive stimulus, is a clinically useful measure of cerebrovascular health. CVR is often measured using a breath-hold task to modulate blood CO<sub>2</sub>levels during an fMRI scan. Measuring end-tidal CO<sub>2</sub>(P<sub>ET</sub>CO<sub>2</sub>) with a nasal cannula during the task allows CVR amplitude to be calculated in standard units (vascular response per unit change in CO<sub>2</sub>, or %BOLD/mmHg) and CVR delay to be calculated in seconds. The use of standard units allows for normative CVR ranges to be established and for CVR comparisons to be made across subjects and scan sessions. Although breath holding can be successfully performed by diverse patient populations, obtaining accurate P<sub>ET</sub>CO<sub>2</sub>measurements requires additional task compliance; specifically, participants must breathe exclusively through their nose and exhale immediately before and after each breath hold. Meeting these requirements is challenging, even in healthy participants, and this has limited the translational potential of breath-hold fMRI for CVR mapping. Previous work has focused on using alternative regressors such as respiration volume per time (RVT), derived from respiration-belt measurements, to map CVR. Because measuring RVT does not require additional task compliance from participants, it is a more feasible measure than P<sub>ET</sub>CO<sub>2</sub>. However, using RVT does not produce CVR amplitude in standard units. In this work, we explored how to achieve CVR amplitude maps, in standard units, and CVR delay maps, when breath-hold task P<sub>ET</sub>CO<sub>2</sub>data quality is low. First, we evaluated whether RVT could be scaled to units of mmHg using a subset of P<sub>ET</sub>CO<sub>2</sub>data of sufficiently high quality. Second, we explored whether a P<sub>ET</sub>CO<sub>2</sub>timeseries predicted from RVT using deep learning allows for more accurate CVR measurements. Using a dense-mapping breath-hold fMRI dataset, we showed that both rescaled RVT and rescaled, predicted P<sub>ET</sub>CO<sub>2</sub>can be used to produce maps of CVR amplitude in standard units and CVR delay with strong absolute agreement to ground-truth maps. The rescaled, predicted P<sub>ET</sub>CO<sub>2</sub>regressor resulted in superior accuracy for both CVR amplitude and delay. In an individual with regions of increased CVR delay due to Moyamoya disease, the predicted P<sub>ET</sub>CO<sub>2</sub>regressor also provided greater sensitivity to pathology than RVT. Ultimately, this work will increase the clinical applicability of CVR in populations exhibiting decreased task compliance.

Imaging NeuroscienceVol. 3
Northwestern University (US), Vanderbilt University (US), McCormick (United States) (US)
Openalex Percentile: Top 22%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.