Embolization of splenic artery aneurysms using coils and n‑butyl 2-cyanoacrylate (NBCA) with a newly developed polytetrafluoroethylene (PTFE)-coated microcatheter: A case series of 3 patients

This retrospective case series evaluates an alternative embolization technique for splenic artery aneurysms (SAA) using a combination of coils and NBCA delivered through a Carry Leon NSX microcatheter, addressing the challenge of unpredictable NBCA behavior in high-risk aneurysms. Three female patients-a 55-year-old, a 60-year-old, and an 80-year-old-presented with SAAs that were either incidentally discovered or demonstrated significant growth over time, prompting intervention due to the potential risk of rupture. Each patient underwent successful embolization via a triple coaxial system that allowed precise coil placement and controlled NBCA injection, resulting in complete aneurysm occlusion with minimal complications such as mild splenic infarction or transient inflammatory responses. These cases demonstrate that the use of a PTFE-coated NSX microcatheter can enhance the safety and efficacy of NBCA injections, reduce the number of coils required, and simplify the embolization procedure, suggesting a promising advancement in the management of visceral arterial aneurysms.

Authors

Institutions

Publication Details

Journal
Radiology Case Reports
Published
2025-03-22
DOI
https://doi.org/10.1016/j.radcr.2025.02.102
Citations
2
Primary Topic
Abdominal vascular conditions and treatments
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Embolization of splenic artery aneurysms using coils and n‑butyl 2-cyanoacrylate (NBCA) with a newly developed polytetrafluoroethylene (PTFE)-coated microcatheter: A case series of 3 patients

Sota Oguro, Hiroyuki Sakakibara, Hiroki Kamada, T. Furukawa et al.
2 citations
Radiology Case Reports
Abdominal vascular conditions and treatments
4.01
article

Embolization of splenic artery aneurysms using coils and n‑butyl 2-cyanoacrylate (NBCA) with a newly developed polytetrafluoroethylene (PTFE)-coated microcatheter: A case series of 3 patients

Sota Oguro, Hiroyuki Sakakibara, Hiroki Kamada, T. Furukawa, Kei Takase, Ken-ichi Ito, Kazuoki Kondo
article en
2 citations

Abstract

This retrospective case series evaluates an alternative embolization technique for splenic artery aneurysms (SAA) using a combination of coils and NBCA delivered through a Carry Leon NSX microcatheter, addressing the challenge of unpredictable NBCA behavior in high-risk aneurysms. Three female patients-a 55-year-old, a 60-year-old, and an 80-year-old-presented with SAAs that were either incidentally discovered or demonstrated significant growth over time, prompting intervention due to the potential risk of rupture. Each patient underwent successful embolization via a triple coaxial system that allowed precise coil placement and controlled NBCA injection, resulting in complete aneurysm occlusion with minimal complications such as mild splenic infarction or transient inflammatory responses. These cases demonstrate that the use of a PTFE-coated NSX microcatheter can enhance the safety and efficacy of NBCA injections, reduce the number of coils required, and simplify the embolization procedure, suggesting a promising advancement in the management of visceral arterial aneurysms.

Radiology Case ReportsVol. 20(6)
Tohoku University Hospital (JP)
Openalex Percentile: Top 8%
Abdominal vascular conditions and treatments
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.