Towards a Validation System for a THz Graphene-Based Epidermal Electronics System

Accurate measurement of muscle activity is essential for biomedical engineering, rehabilitation, and prosthetic development. This study investigates the use of High-Density Electromyography (HD-EMG) to validate in the future a novel THz-based epidermal electronic system. HD-EMG, known for its high resolution and detailed muscle activity analysis, was employed on the Musculus flexor carpi radialis to detect innervation zones. The experimental setup included isometric contractions at 30 % and 60 % maximum voluntary contraction (MVC), recorded using HD-EMG grids. Results showed consistent 180-degree phase shifts between specific channels, indicating the presence of innervation zones. These findings support HD-EMG as a reliable ground truth for validating advanced epidermal electronic systems. Future research should involve a larger and more diverse sample and explore additional features of muscle activity, including the observation of zero lines and various MVC levels.

Authors

Institutions

Publication Details

Published
2025-02-23
DOI
https://doi.org/10.1109/icmmts62835.2025.10925981
Primary Topic
Semiconductor materials and interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards a Validation System for a THz Graphene-Based Epidermal Electronics System

Elsa Andrea Kirchner, Niels Benson, Sabisan Santhakumaran
Semiconductor materials and interfaces
article

Towards a Validation System for a THz Graphene-Based Epidermal Electronics System

Elsa Andrea Kirchner, Niels Benson, Sabisan Santhakumaran
article en

Abstract

Accurate measurement of muscle activity is essential for biomedical engineering, rehabilitation, and prosthetic development. This study investigates the use of High-Density Electromyography (HD-EMG) to validate in the future a novel THz-based epidermal electronic system. HD-EMG, known for its high resolution and detailed muscle activity analysis, was employed on the Musculus flexor carpi radialis to detect innervation zones. The experimental setup included isometric contractions at 30 % and 60 % maximum voluntary contraction (MVC), recorded using HD-EMG grids. Results showed consistent 180-degree phase shifts between specific channels, indicating the presence of innervation zones. These findings support HD-EMG as a reliable ground truth for validating advanced epidermal electronic systems. Future research should involve a larger and more diverse sample and explore additional features of muscle activity, including the observation of zero lines and various MVC levels.

University of Duisburg-Essen (DE)
Openalex Percentile: Top 96%
Semiconductor materials and interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards a Validation System for a THz Graphene-Based Epidermal Electronics System — Elsa Andrea Kirchner, Niels Benson, et al. · (2025) | TGRS Research Map | TGRS