Quality Optimization and Equivalence Evaluation of Radiographic Digital Images of Aluminum Alloy Welds in Launch Vehicles

Aiming at the problem of unclear influence of technological parameters on image quality in digital radiography (DR) of welds in carrier rocket storage tanks, 6mm(transillumination thickness)fusion welds/friction stir welds were taken as the research object. The influences of tube voltage, exposure, focus size, magnification, pixel size, integral noise reduction frame number on image sensitivity, normalized signal-to-noise ratio and spatial resolution were analyzed, which provided theoretical basis of guiding the optimization of detection process. On the basis of this, digital radiography and film photography were performed on the welds of the storage tank, and the differences in defect morphology, size, distribution, and other aspects were compared and analyzed. The results show that the image sensitivity, spatial resolution, and normalized signal-to-noise ratio of 6mm welds digital radiography results are better than the A-level technical requirements. The detection results are basically consistent with the film photography detection results, and the size measurement error is less than 3%.

Authors

Publication Details

Published
2024-10-31
DOI
https://doi.org/10.1109/icsmd64214.2024.10920509
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality Optimization and Equivalence Evaluation of Radiographic Digital Images of Aluminum Alloy Welds in Launch Vehicles

Chul Kyu Jin, Wang Tu, Fei Wang, Wenqiang Wang et al.
Advanced X-ray and CT Imaging
article

Quality Optimization and Equivalence Evaluation of Radiographic Digital Images of Aluminum Alloy Welds in Launch Vehicles

Chul Kyu Jin, Wang Tu, Fei Wang, Wenqiang Wang, Wei Quan, Yao Huang
article en

Abstract

Aiming at the problem of unclear influence of technological parameters on image quality in digital radiography (DR) of welds in carrier rocket storage tanks, 6mm(transillumination thickness)fusion welds/friction stir welds were taken as the research object. The influences of tube voltage, exposure, focus size, magnification, pixel size, integral noise reduction frame number on image sensitivity, normalized signal-to-noise ratio and spatial resolution were analyzed, which provided theoretical basis of guiding the optimization of detection process. On the basis of this, digital radiography and film photography were performed on the welds of the storage tank, and the differences in defect morphology, size, distribution, and other aspects were compared and analyzed. The results show that the image sensitivity, spatial resolution, and normalized signal-to-noise ratio of 6mm welds digital radiography results are better than the A-level technical requirements. The detection results are basically consistent with the film photography detection results, and the size measurement error is less than 3%.

Affordable and clean energy
Openalex Percentile: Top 75%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.