Research on Testing of the Proton Conduction Resistance for the PEMWE

The proton exchange membrane water electrolyzer (PEMWE) is a crucial device for hydrogen production, both currently and in the future, due to its environmentally friendly, safe, efficient, and long-lasting characteristics, as well as its rapid start-up capabilities, which confer significant commercial value. Proton conduction resistance of the anode catalyst layer for a PEMWE is an important impedance component that affects the performance of PEMWE. In trying to obtain the accurate proton conduction resistance, this study conducts experiments based on the different relative humidities, and applied voltages. The results indicate that the minimum proton conduction resistance was achieved under the conditions of 100% anode relative humidity, 148% cathode relative humidity, and an applied testing voltage of 1.0-1.2 V. Moreover, the anode catalyst layer of the electrolyzer with a Nafion content of 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> exhibits low proton conduction resistance and optimal performance.

Authors

Institutions

Publication Details

Published
2024-10-31
DOI
https://doi.org/10.1109/icsmd64214.2024.10920310
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Testing of the Proton Conduction Resistance for the PEMWE

Mingruo Hu, Kequan Ye, Fengjing Jiang, Hao Zhang et al.
2 links
Particle accelerators and beam dynamics
article

Research on Testing of the Proton Conduction Resistance for the PEMWE

Mingruo Hu, Kequan Ye, Fengjing Jiang, Hao Zhang, Qing Wang
article en

Abstract

The proton exchange membrane water electrolyzer (PEMWE) is a crucial device for hydrogen production, both currently and in the future, due to its environmentally friendly, safe, efficient, and long-lasting characteristics, as well as its rapid start-up capabilities, which confer significant commercial value. Proton conduction resistance of the anode catalyst layer for a PEMWE is an important impedance component that affects the performance of PEMWE. In trying to obtain the accurate proton conduction resistance, this study conducts experiments based on the different relative humidities, and applied voltages. The results indicate that the minimum proton conduction resistance was achieved under the conditions of 100% anode relative humidity, 148% cathode relative humidity, and an applied testing voltage of 1.0-1.2 V. Moreover, the anode catalyst layer of the electrolyzer with a Nafion content of 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">%</sup> exhibits low proton conduction resistance and optimal performance.

Shanghai Jiao Tong University (CN), CIC energiGUNE (ES)
Openalex Percentile: Top 53%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.