Research on Spectral Radiance Stability Under UV Region of Deuterium Lamp

Deuterium lamps are important light sources in the ultraviolet band, particularly for applications in ultraviolet photoelectron spectrometers. The research employed three stability measurement methods: Coefficient of Variation (CV), Peak-Peak (P-P), and Range Normalization Index (RNI), to assess the stability across different wavelengths. The results indicate that the stability varies significantly with wavelength, with the best performance observed at 250 nm. The stability at near-UV wavelengths is better than that at vacuum UV wavelengths. Long-term operation leads to a decrease in spectral radiance, suggesting factors such as filament aging, power supply instability, and contamination of the vacuum system may be the potential causes. The research underscores the importance of regular maintenance to ensure optimal performance and stability of deuterium lamps in scientific research and industrial applications.

Authors

Institutions

Publication Details

Published
2024-10-31
DOI
https://doi.org/10.1109/icsmd64214.2024.10920550
Primary Topic
Impact of Light on Environment and Health
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Spectral Radiance Stability Under UV Region of Deuterium Lamp

Xiaohan Hou, Bowei Tong, Sichao Zhang, Hisao Ishii et al.
Impact of Light on Environment and Health
article

Research on Spectral Radiance Stability Under UV Region of Deuterium Lamp

Xiaohan Hou, Bowei Tong, Sichao Zhang, Hisao Ishii, Yu Chen, Linhuan Wei, Shuang Wang, S. X. Du, Yali Guo
article en

Abstract

Deuterium lamps are important light sources in the ultraviolet band, particularly for applications in ultraviolet photoelectron spectrometers. The research employed three stability measurement methods: Coefficient of Variation (CV), Peak-Peak (P-P), and Range Normalization Index (RNI), to assess the stability across different wavelengths. The results indicate that the stability varies significantly with wavelength, with the best performance observed at 250 nm. The stability at near-UV wavelengths is better than that at vacuum UV wavelengths. Long-term operation leads to a decrease in spectral radiance, suggesting factors such as filament aging, power supply instability, and contamination of the vacuum system may be the potential causes. The research underscores the importance of regular maintenance to ensure optimal performance and stability of deuterium lamps in scientific research and industrial applications.

Chiba University (JP), Xi'an Jiaotong University (CN)
State Key Laboratory of Electrical Insulation and Power Equipment, National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 77%
Impact of Light on Environment and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Spectral Radiance Stability Under UV Region of Deuterium Lamp — Xiaohan Hou, Bowei Tong, et al. · (2024) | TGRS Research Map | TGRS